Fig. 26: FirNet™ – Opening the Update Scene + Filter Settings dialog

Fig. 27: FirNet™ – Selecting filters and controllers

4.2 Loading a single filter

Open the Controller/Save Filter to Controller dialog and select the filter from
the file in the newly created folder.
Heads up: Always wait until the devices finish loading filters. A message will
appear on your desktop.

Fig. 28: FirNet™ – Opening the dialog box for loading individual filters

Then go to the Admin window and enter the correct values for Max Output
level (+6 dB for HK AUDIO VX 2400 amps, +18 dB for Lab.Gruppen FP 10000Q
amps).

Fig. 29: FirNet™ – Admin menu settings

For more info, read the LIPAN software’s and FIRNET controller’s operating
manuals, which are also on the included CD-Rom.

You’ll find all the latest files for downloading on our website at
www.hkaudio.com.

FirNet Display

The LCD shows information on presets and parameters. The default readout
appears after the device is powered up, and then the display indicates current
speaker selection settings and the LAN status. Once you begin navigating ad-
justable parameters, it shows values pertaining to these parameters.

FirNet Menu Keys

Menu keys (Speaker, Level, Scene, Delay/Phase und Admin) serve to access the
various parameter sections. You can adjust the indicated parameters and save
these settings using the edit select keys (cursors and back key) for the selected
input and output. Pressing the back key always takes you to the next higher
menu level.
Note: The device retains stored values even if a power failure occurs or it is
unplugged from the mains supply.

FirNet Channel Mute

• Using Channel Mute Shortcuts to Mute Outputs A/B/C/D
You can use combinations of the Admin menu key and the four other menu keys
(Speaker, Scene, Level, Delay/Phase) to mute the FIRNET’s output channels in
A/B/C/D sequence. For example, if you wish to mute output A, press Admin +
Speaker; to mute output D, press Admin + Delay/Phase. Press the same combi-
nation again to reactivate the output.
Note: Each of the output channels’ red signal LEDs show the given output’s
mute status (constant red = MUTE).