List of the control characters in use – Baumer NE214 Benutzerhandbuch

Seite 13

Advertising
background image

NE214

www.baumer.com

13

Error description in particular:

Error 1 : Format error (<ETX> not in correct position). This error may occur for
example if the data format has not been observed when programming
(e.g.: when programming the Start Count, only 5 digits instead of 6
are transmitted).

Error 2 : Line (position) not available or separating line

Error 3 : Parameter error (non-admissible value in protocol). This means, for
example, that the scaling factor does not only consist of digits, but
also of other non-admissible characters, or that a value has been
indicated that is not within an admissible range.

7. List of the control characters in use

Control character

Hex

Decimal

<STX> 02

02

<ETX> 03

03

<ACK> 06

06

<LF> 0A

10

<CR> 0D

13

<DC1> 11

17

<CAN> 18

24

<DEL> 7F

127




























Advertising