Programming plan, Ne214 – Baumer NE214 Benutzerhandbuch
Seite 15
NE214
www.baumer.com
15
9. Programming plan
Lines 11-16 Status for Line 1-6
0
Parameter can be changed
1
Clearing of and/or Input disabled
2
Parameter is skipped
Line 22
Operating modes
0
Progressive preselection
1
Principal preselection
2
Parallel comparison
3
P1 trailing preselection
Line 23
Scaling factor
1.0000
Default
00.0001 Min.
9999.99
Max.
Line 24
Decimal point
0
No decimal point
1
00000.0
2
0000.00
3
000.000
4
00.0000
Line 25
Type of counting
0
Track A possibly UP/DOWN-Signal on track B
1
Subtraction (A-B)
2
Totaling (A+B)
3
Track A 90° B Single evaluation
4
Track A 90° B Double evaluation
5
Track A 90° B Quadruple evaluation
Line 26
Frequency Principal counter Track A
0
10 kHz
1
25 Hz
2
3 Hz
Line 27
Frequency Principal counter Track B
0
10 kHz
1
25 Hz
2
3 Hz
Line 28
Input logic
0
PNP - Operating threshold 11V
1
NPN - Operating threshold 11V
2
PNP - Operating threshold 5V
3
NPN - Operating threshold 5V
4
PNP - Operating threshold 2,5V
5
NPN - Operating threshold 2,5V
Line 29
Reset Principal counter
0
Autom. Reset and ext. static
1
Autom. Reset and ext. diff.
2
External static
3
External diff.
Line 31
Function Signal input 9
0
Stop
1
Hold
2
Keylock
3
Operating time meter ON/OFF
4
Line 33
Output logic for digital outputs
0
Both outputs as Make contacts
1
P1 Break contact, P2 Make contact
2
P1 Make contact, P2 Break contact
3
Both outputs as Break contacts
Line 35
Impulse signal time P1
0.25
Default
0.01
Min.
99.99
Max.
Line 36
Impulse signal time P2
0.25
Default
0.01
Min.
99.99
Max.
Line 37
Take-over of preselections P1,P2
0
Immediately effective
1
With reset
Line 38
Preselection recognition
0
Only with positive range
1
With positive and negative counting range