9 programming plan – Baumer NE213 Benutzerhandbuch

Seite 15

Advertising
background image

NE212 / NE213

www.baumer.com

15

9 Programming plan

Line 11-18

Status for Lines 1-8

0

Parameter can be altered

1

Deletion or input inhibited

2

Parameters bypassed

Line 21

Operating mode, main counting system

0

Stage preselection

1

Main preselection

2

Parallel comparison

3

P1 slave preselection

Line 22

Scaling factor, main counting system

1.0000

Minimum value

0.0001

Default value

9999.99

Maximum value

Line 23

Scaling factor, ancillary counting system

1

Minimum value

1

Default value

99

Maximum value

Line 24

Frequency track A

0

10 kHz

1

25 Hz

2

15 Hz

Line 25

Frequency track B

0

10 kHz

1

25 Hz

2

15 Hz

Line 26

Frequency batch counting input

0

10 kHz

1

25 Hz

2

15 Hz

Line 27

Operating modes, inputs

0

Track A and Up/Down

1

Differential counting A - B

2

Summation

3

A 90

° B

4

A 90

° B x 2

5

A 90

° B x 4

Line 28

Decimal point, main counting system

0

No decimal point

1

0000000.0

2

000000.00

3

00000.000

Line 29

Resetting, main counting system

0

Automatic reset and external static

1

Automatic reset and external differentiated

2

External static

3

External differentiated

Line 30

Resetting, ancillary counter

0

Automatic reset and external static

1

Automatic reset and external differentiated

2

External static

3

External differentiated

Line 31

Output P1

0.25

Continuous

0.01

Default

99.99

Maximum

Line 32

Output P2

0.25

Continuous

0.01

Default

99.99

Maximum

Line 33

Output P3

0.25

Continuous

0.01

Default

99.99

Maximum

Line 34

Acceptance of preselections P1, P2, B

0

On

1

Following

Line 35

Address for function key

0

Without function

1

XP

2

P1

3

P2

4

SC

7

Σ

5

XB

6

B1

8

§

Line 36

Function of the batch counter

0

External

1

Internal

2

Tachometer

Line 37

Pulses per unit with tachometer

1.00

Minimum value

0.01

Default value

9999.99

Maximum value

Line 38

Time basis for tachometer function

0

1 second

1

2 seconds

2

3 seconds

3

6 seconds

4

10 seconds

5

20 seconds

6

30 seconds

7

60 seconds

Line 39

Assignment output 3

0

Batch preselection output

1

Zero contact output XP

Line 40

Function input 15

0

XP Stop

1

Operating hours ON/OFF

2

Key and display hold

Line 41

Code

0000

Code not active

:

9999

Line 43

Baud rate

0

4800 Baud

1

2400 Baud

2

1200 Baud

3

600 Baud

Line 44

Parity

0

Even Parity

1

Odd Parity

2

No Parity

Line 45

Address

00

Default

00

Min.

99

Max.

Line 46

Stop bits

0

1 Stop bit

1

2 Stop bits

Advertising