When the error message is returned, the two positions "line" und "mode" are dropped

Detailed error description:

Error 1 :

Format error(<ETX> is not positioned correctly). This error occurs

e.g. if the data format is not observed during the programming(e.g.:

when programming the start value, only 5 data positions are

transmitted instead of 6)


Error 2 :

Line(position) does not exist or separation line


Error 3 :

Parameter error(invalid values in the protocol). That

means, for example, that the scaling factor does not only consist

of numerals but also of other invalid signs or that a given value

is

not

within

a

permissible

range.

6. List of the control characters used

Control character

Hex

Decimal

<STX> 02

02

<ETX> 03

03

<ACK> 06

06

<LF> 0A

10

<CR> 0D

13

<DC1> 11

17

<CAN> 18

24

<DEL> 7F

127


7. Operating scheme

Line

Factory setting

Customer program

Brief description

01

0

XP – Counter count main counter

20

- - - - - -

Separation

line

21

2 1 S F

2 1

Start

value

1.0 0 0 0

23

2 3 S F

2 3

Scaling

factor

1.0 0 0 0

24

2 4 0

2 4

Decimal

point

25

2 5 0

2 5

Counting

mode

26

2 6 0

2 6

Frequency main counter track A

27

2 7 0

2 7

Frequency main counter track B

28

2 8 0

2 8

Input

logic

29

2 9 0

2 9

Reset main counter

30

3 0 0

3 0

Reset key function enable on operating level

31

3 1 0

3 1

Function signal input 9

32

3 2 0

3 2

Output contact assignment

33

3 3 0

3 3

Output logic for digital output

34

3 4 0

3 4

Output contact function

35

3 5 t 1

3 5

Impulse signal time P1

0.2 5

40

4 0 C o d

4 0

Code

0

51

5 1 0

5 1

Baud

rate

52

5 2 0

5 2

Parity

53

5 3 0

5 3

Stop

bits

54

5 4 0

5 4

Address

67

- - - - - -

Separation

line

Advertising