Baumer BA_DACx_800 Benutzerhandbuch
Seite 2
Baumer Electric AG
3/40
www.baumerelectric.com
Frauenfeld, Switzerland
DACU/I BA V2.1M
1
Functional description .................................................................................................................22
2
Safety and operating notes .........................................................................................................22
2.1
Use as specified .............................................................................................................................22
2.2
Putting into operation .....................................................................................................................22
2.3
Safety notes....................................................................................................................................22
2.4
Transport and storage ....................................................................................................................22
2.5
Organizational actions ....................................................................................................................22
3
Mounting .......................................................................................................................................23
4
Function ........................................................................................................................................23
4.1
Block diagram.................................................................................................................................23
4.2
Electrical connections.....................................................................................................................25
4.3
Measuring ranges...........................................................................................................................27
5
Start up ..........................................................................................................................................28
5.1
Connecting on controller side.........................................................................................................28
5.2
Connect on sensor side..................................................................................................................28
5.3
Setting the measurement ranges ...................................................................................................29
5.4
Alarm outputs .................................................................................................................................31
5.5
RESET function ..............................................................................................................................32
5.6
PEAK function ................................................................................................................................32
5.7
80% test..........................................................................................................................................32
5.8
Identification of charge amplifier.....................................................................................................33
6
Serial Interface (DACU 800 only) ................................................................................................34
6.1
Description......................................................................................................................................34
6.2
Data format Master.........................................................................................................................34
6.3
Data format Slave...........................................................................................................................37
7
Technical data ...............................................................................................................................38
7.1
Electrical data .................................................................................................................................38
7.2
Mechanical data .............................................................................................................................39
7.3
Ambient conditions .........................................................................................................................39
7.4
Dimensions.....................................................................................................................................39
8
Accessories ..................................................................................................................................39
9
Service...........................................................................................................................................40
Baumer Electric AG
4/40
www.baumerelectric.com
Frauenfeld, Switzerland
DACU/I BA V2.1M
1 Funktionsbeschreibung
Der DACU/I 800 ist ein Mehrbereichsladungsverstärker für den industriellen Einsatz. Er wandelt die
von einem piezoelektrischen Sensor abgegebene Ladung in ein proportionales Spannungssignal
(DACU 800) oder Stromsignal (DACI 800) um. Durch seinen extrem grossen Ladungsbereich von
100pC – 1'000’000pC ist der DACU/I für fast alle piezoelektrischen Messaufgaben geeignet.
•
geringe Drift der Messkette durch abgeglichene Eingangsoffsetspannung
•
robustes Aludruckguss-Gehäuse
•
13 fixe Bereiche
•
1 einstellbarer Bereich
•
Test-Funktion
•
Spitzenwertspeicher
•
einstellbare Grenzwerte mit Schaltausgängen
•
Serielle Schnittstelle RS 232 (nur DACU 800)
2 Sicherheits- und Betriebshinweise
2.1 Bestimmungsgemässer Gebrauch
•
Der Ladungsverstärker darf ausschliesslich in den für ihn spezifizierten Leistungen betrieben
werden.
2.2 Inbetriebnahme
•
Einbau und Montage des Ladungsverstärkers darf ausschliesslich durch eine Elektrofachkraft
erfolgen.
•
Verdrahtungsarbeiten am Stecker oder im Schaltschrank dürfen nur in spannungslosem Zustand
durchgeführt werden.
•
Betriebsanleitung des Maschinenherstellers beachten.
2.3 Sicherheitshinweise
•
Vor Inbetriebnahme der Anlage alle elektrischen Verbindungen überprüfen.
•
Wenn die Montage, das elektrische Anschliessen oder sonstige Arbeiten am Ladungsverstärker
nicht fachgerecht ausgeführt werden, kann es zu Fehlfunktionen oder Ausfall des
Ladungsverstärkers kommen.
•
Gefährdung von Personen, Beschädigung der Anlage und Betriebseinrichtungen durch Ausfall
oder Fehlfunktion des Ladungsverstärkers muss durch geeignete Sicherheitsmassnahmen
ausgeschlossen werden.
•
Der Ladungsverstärker darf nicht ausserhalb der Grenzwerte betrieben werden, welche in den
Technischen Daten (s. Kapitel 6) angegeben sind.
Nichtbeachtung der Sicherheitshinweise kann zu Fehlfunktionen, Sach- und
Personenschäden führen!
2.4 Transport und Lagerung
•
Transport und Lagerung nur in Originalverpackung
•
Ladungsverstärker nicht fallen lassen oder grösseren Erschütterungen aussetzen
2.5 Organisatorische Massnahmen
•
Stellen Sie sicher, dass das Personal die Betriebsanleitung und hier besonders das Kapitel
„Sicherheits- und Betriebshinweise“ gelesen und verstanden hat.
•
Ergänzend zur Betriebsanleitung allgemeingültige gesetzliche und sonstige verbindliche
Regelungen zur Unfallverhütung und zum Umweltschutz beachten und sicherstellen.