12.2 Command mode

In a single sensor configuration this mode allows a transmission of the measured values with maxi-
mum speed and no protocol overhead. The measuring type cannot be changed in this mode. It must
be set before using the button.

There are eight commands with one byte for master sensor communication.

0xYZ means: this is one byte with the hexadecimal value of YZ

command

Function

Response

0xFF

Request for measured value
(0 .. 1023) standard

2 Byte binary
1.Hi Byte 2. Low Byte

0xAA

Request for measured value
with HiRes (0..4095)

2 Byte binary
1. Hi Byte 2. Low Byte

0x08

Switch to protocol mode

None

0x0A

Continuous data
(0 .. 1023) standard

2 Byte binary
Hi Byte (data: Bit 0..4, Bit 7 = 1)
Low Byte (data: Bit 0..4, Bit 7 = 0)
Sensor sends continuously data until the
sensor receive 0xFF or 0x08

0x0C

Continuous data
with HiRes (0..4095)

2 Byte binary
Hi Byte (data: Bit 0..5, Bit 7 = 1)
Low Byte (data: Bit 0..5, Bit 7 = 0)
Sensor sends continuously data until the
sensor receive 0xFF or 0x08