12.2 Command mode
In a single sensor configuration this mode allows a transmission of the measured values with maxi-
mum speed and no protocol overhead. The measuring type cannot be changed in this mode. It must
be set before using the button.
There are eight commands with one byte for master sensor communication.
0xYZ means: this is one byte with the hexadecimal value of YZ
command
Function
Response
0xFF
Request for measured value
(0 .. 1023) standard
2 Byte binary
1.Hi Byte 2. Low Byte
0xAA
Request for measured value
with HiRes (0..4095)
2 Byte binary
1. Hi Byte 2. Low Byte
0x08
Switch to protocol mode
None
0x0A
Continuous data
(0 .. 1023) standard
2 Byte binary
Hi Byte (data: Bit 0..4, Bit 7 = 1)
Low Byte (data: Bit 0..4, Bit 7 = 0)
Sensor sends continuously data until the
sensor receive 0xFF or 0x08
0x0C
Continuous data
with HiRes (0..4095)
2 Byte binary
Hi Byte (data: Bit 0..5, Bit 7 = 1)
Low Byte (data: Bit 0..5, Bit 7 = 0)
Sensor sends continuously data until the
sensor receive 0xFF or 0x08