Programming plan – Baumer NE230 Benutzerhandbuch

Seite 15

Advertising
background image

NE230

www.baumer.com

15

9. Programming plan

Lines
11-17

status of lines 1-7

0

parameter to be altered

1

clear resp. input lock

2

skip parameter

Line 22

operation mode

0

step preset

1

main preset

2

parallel comparison

3

P1 trailing preset

Line 24

decimal point

0

no decimal point

1

00000.0

2

0000.00

3

000.000

4

00.0000

Line 25

counting mode

0

track A UP/DOWN signal on track B

1

difference (A-B)

2

total (A+B)

3

track A 90° B single evaluation

4

track A 90° B double evaluation

5

track A 90° B four-times evaluation

Line 26

frequency main counter track A

0

10 kHz

1

25 Hz

2

3 Hz

Line 27

frequency main counter track B

0

10 kHz

1

25 Hz

2

3 Hz

Line 28

switching threshold and input logic

0

switching threshold 6V PNP

1

switching threshold 6V NPN

2

switching threshold 3V PNP

3

switching threshold 3V NPN

Line 29

main counter reset (control input 1)

0

automatic reset and externally static

1

automatic reset and externally differential

2

externally static

3

externally differential

4

externally with "start-function"

Line 31

function control input 2

0

stop

1

hold

2

keylock

3

hour counter on/off

4

offset

5

print (only with interface)

Line 33

output logic digital outputs

0

both outputs normally closed

1

P1 normally open, P2 normally closed

2

P1 normally closed, P2 normally open

3

both outputs normally open

Line 35

momentary signal time P1

0.25

default

0.01

Min.

99.99

Max.

Line 36

momentary signal time P2

0.25

default

0.01

Min.

99.99

Max.

Advertising