Baumer NE230 Benutzerhandbuch

Seite 16

Advertising
background image

NE230

16 www.baumer.com

Line 37

activation of presets P1, P2

0

immediately active

1

after reset

Line 38

counting range P1,P2 and SC

0

positive only

1

positive and negative

Line 39

function key assignment

0

w/o function

1

XP

2

P1

3

P2

4

SC

5

Σ

6

Á

7

SF

Line 40

code

0000

code not active

:

9999

Line 41

batch counter function

0

totalizer

1

counting upon achieving P2

Line 42

batch counter multiplier (Line 41=1)

1

default

0

min.

999

max.

Line 43

offset

0

no offset

:

999999

max. offset value

Line 44

mains failure display

0

no mains failure display

1

mains failure display (blinking)

Line 51

Baud rate

0

4800 Baud

1

2400 Baud

2

1200 Baud

3

600 Baud

Line 52

parity

0

even parity

1

odd parity

2

no parity

Line 53

stop bits

0

1 stop bit

1

2 stop bits

Line 54

counter identification

00

default

00

min.

99

max.

Line 55

output value assignment by interface
Line 31=5

0

display value

1

XP

2

P1

3

P2

4

SC

5

Σ

6

Á

7

SF

Line 56

RS422: control connections TxD+ , TxD-

0

In sending direction during sending, in receiving direction during reception

1

always in sending direction

Advertising