Installation, Installation and operating instructions – Pilz PSENme 4A Benutzerhandbuch

Seite 6

Advertising
background image

Installation and Operating Instructions

Installation

Installation by trained and qualified personnel only!


To mount the switch gear 2 screws M5 shall be used.

Actuator PSEN me4AS:
The user shall make sure that the actuator is form-fit mounted. The actuator mounting should not be solvable with
simple tools. For a tamperproof mounting use one-way screws of M 4X8 size.
The switch and the actuator shall be aligned during installation in such a way that even after multiple actuations of
the safety guard no lateral forces affect the actuator head.

The mounting position is any desired but shall support inspection and replacement if necessary by qualified
personnel. Choose such a mounting position that no foreign parts seep into the opening of the actuating device.

The rated degree of protection (IP-Code) of the switch applies only with closed cover lid and when an at least evenly
matched cable gland with adequate cable is used.

The switches shall not be used as mechanical end stop.


The safety switch shall not be used as
mechanical end stop!

Position of
mechanical stop adjustable
(not supplied with
safety switch)

4 different directions of actuation by turning the cap
from 0° to 270°:

1. draw clasp out
2. turn actuator head
3. press-on clasp

Cover for unused entry

Actuating forces (Extraction force):

Standard = 10 N

PSEN me4.01, PSEN me4.11,
PSEN me4.21 = 50 N

Connecting the cable:

Connection type:
2 or 4 screw connectors M3,5 or
6 screw connectors M3
Conductor cross section:
single core 0,5-1,5 mm²/litz wire with
connector sleeve 0,5-1,5 mm²

Date of issue: 15.04.2014 / Page 6 of 8

1003289-2EN-03 / Document: 0800000424 / Version: 3 / 2220-14

Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Straße 2, D-73760 Ostfildern, Deutschland
Phone: +49 711 3409-0, Fax: +49 711 3409-133, E-Mail: [email protected], www.pilz.com

Template : 0850174292 Orig. 2

Advertising