6156-2002

Specifications LD-02 AC

Transmission

Asynchronous, full/half duplex or simplex

Interface 1

EIA RS-232-C/V.24 fixed on channel 1

Interface 2

10mA balanced current loop fixed on channel 2 and 3

Interface 3

EIA RS-422/485/CCITT V.11 on channel 4

Connection

Channel 1: 9 pin D-sub female
Channel 4: 5 pos screw-terminal
Channel 2 and 3: 9 pos screw-terminal

Max. recommended no
of LD-02’s in series

14 pcs

Transmission rate

Data rates up to 38 400 bit/s

Indicators

Power, RD, TD, DCD2, DCD3

Isolation

Galvanic isolation with opto-coupler (data transmission)
and transformer (supply)

Isolation voltage

1500V

Overvoltage protection

Mains: Breakdown voltage 430V at 230V AC
Interface 2: Breakdown voltage transmitter 15V,
receiver 5.8 V. Surge capacity 0.6 kW during 1 ms
Interface 3: Breakdown voltage receiver and
transmitter 7V. Surge capacity 0.6 kW during 1 ms

Power supply

230V 48-62Hz +15/–10%

Fuse

100mA fast 5x20 mm

Power consumption**

Max 25mA at 230V

Temperature range

5-50°C, ambient temperature

Humidity

0-95% RH, non-condensing

Dimension

55x100x128 mm

Weight

0.4 kg

Mounting

On 35mm DIN-rail

Specifications LD-02 AC 115V*

Overvoltage protection

Mains: Breakdown voltage 220V at 115V AC

Power supply

115V AC +15/–10% 48-62Hz

Power consumption

Max 50mA at 115V

Specifications LD-02 DC*

Power supply

12-36V DC

Power consumtion

Max 3W

Isolation

500V

Fuse F1

1.6A fast acting 5x20 mm