9

6044-2002

Specifications MA-44

Transmission

Asynchronous, full/half duplex or simplex

Interface 1

EIA RS-232-C/CCITT V.24
25-position D-sub female, DCE

Interface 2

EIA RS-422/RS-485/CCITT V.11

Data rate

Up to 38.4 kbit/s

Indicators

Power, RD, DCD, CTS, RTS, TD

Insulation

Galvanic insulation with opto-coupler (data transmission)
and transformer (supply)

Insulation voltage

1 500 V

Overvoltage protection

Mains: Breakdown voltage 440 V at 230 V AC and 220 V

at 115 V AC
Interface 2: Breakdown voltage transmitter and
receiver 7 V. Surge capacity 0.6 kW for 1ms

Power supply

Switchable 115/230 V +15/–10% 48–62 Hz

Fuse

100 mA fast 5x20 mm

Power consumption

Max 5 VA at 230 V

Temperature range

5–50°C, ambient temperature

Humidity

0–95% RH, non-condensing

Dimensions

161x139x53 mm (WxDxH)

Weight

0.5 kg

Mounting

With rubber pads or screws. Screws:
Remove the two ”keyholes” on the bottom of the case