Warning: The unit must be permanently connected to the protective ground before operation. The
cross-sectional area of the protective earthing / grounding conductor shall be at least 10 mm

2

or

6 AWG.
Warnung: Diese Anlage muss vor der Inbetriebnahme ständig an den Schutzleiter angeschlossen

werden. Die Querschnittsfläche des Schutzerdungsleiters soll mindestens 10 mm

2

oder 6 AWG

betragen.

警告:进行设备操作前,请确保设备永久接地,并且确保接地线截面不小于

10 mm

2

或6 AWG。

Warning: Before the power cable is connected, it must be confirmed that the power cord complies
with the requirements of the actual installation (see power cord table)

Warnung: Überprüfen Sie vor dem Anbringen der Zuleitung immer, ob das von Ihnen verwendete
Kabel den Anforderungen entspricht (siehe Netzkabel-Tabelle).

警告

: 在进行电源线连接前,请确保电源线与实际安装要求一致(参考电源线表格)。

Warning Power Cord Table:
The power cord set must be approved for the country where it is used.
WARNUNG Netzkabel Tabelle:
Das Netzkabel muss für das Land, in dem es verwendet wird, zugelassen werden.
警告:电源线表格:

电源线组件必须满足使用的国家认证要求。

U.S.A. and
Canada

The cord set must be UL approved and CSA certified

The minimum specification for the flexible cord is:

No. 14 AWG

Type SV / SVT or SJ / SJT or SPT-2

3 conductor

The cord set must have a rated current carrying capacity of at least 20A.

The attachment plug must be an earth-grounding type with a NEMA 5-20

(20A, 125V) or NEMA 6-20 (20A, 250V) configuration

United Kingdom

The supply plug must be a 2 pole plug with dual earth contacts as per
IEC 60309.

The mains cord must <HAR> or <BASEC> marked and be of type
H05VVF3G1.50 (minimum)

Europe

The supply plug must comply with CEE 7/7 (“SCHUKO”)

The mains cord must <HAR> or <BASEC> marked and be of type

H05VVF3G1.50 (minimum)

Denmark

The supply plug must comply with the Heavy Current Regulations, section
107-2-D1 or EN60309-2.

Switzerland

The supply plug must comply with SEV/ASE 1011

Argentina

The power cord set must be certified by UL, IRAM, TÜV (or other
authorized certification body), for three conductors cables.

The attachment plug must be an earth-grounding type with an

IRAM-2073 (20 A, 250 V).

中国

电源线组件必须通过

CCC 认证。

必须使用符合

GB1002,额定值为 250V/16A 的单相两级带接地插头

电源线最小线径为

1.5mm

2

The appliance coupler (the connector to the unit and not the connector to the wall plug) must have a

configuration for mating with an EN 60320 / IEC 320 C19 appliance inlet.