Using the accessories (see ill. d), Cleaning and care – Parkside PABK 60 A1 Benutzerhandbuch

Seite 11

Advertising
background image

11

GB/IE/CY

Using the accessories (see Ill. D)

Air mattress adapter

6

, ball needle

12

Use a pipe wrench to unscrew the nozzle

9 a

of

the air blow gun

9

.

Then – depending on what is needed – screw

on the air mattress adapter

6

or the ball nee-

dle

12

, as well as the thread adapter

7

into

the barrel of the air blow gun

9

.

Universal valve connection

10

Screw the universal valve connection

10

directly

onto the compressed air hose

8

.

Cleaning and care

Thoroughly clean the spray stylus

3

immedi-

ately after use. Otherwise the paint can dry and
cause problems during the next use.

Thoroughly rinse out the spray stylus

3

with

water.

Use the thinner included to clean any stubborn

dried paint.
Note: The thinner is not suitable for water-so-
luble paints. Rather, it corresponds to a varnish
for thinning paints containing solvents.
Note: If you remove the paint nozzle of the
air blow gun

9

during cleaning, lubricate the

threads before reattaching it so its freedom of
movement is not affected.

Never lay the entire air blow gun

9

in a sol-

vent bath.
Note: If the air intake of the compressor should
become dirty, use a dry cloth to remove the ac-
cumulated dirt.

Fault

Interrupted paint jet

or intermittent paint

delivery

Cause

Solution

1. Paint almost

empty

1. Fill paint

2. Paint too viscous 2. Lower viscosity
3. Dry / defective

nozzle

3. Screw in nozzle tightly

or replace

Fault

Interrupted paint jet

or intermittent paint

delivery

Cause

Solution

4. Paint supply

restricted

4. Cleaning

5. Incorrect posi-

tion of spray

stylus

3

.

5. Correct position angle

Fault

Spray pattern

incomplete

Cause

Solution

1. Air head

dirty / defective

1. Clean / replace air head
1. Rinse with clear water

2. Nozzle dirty /

defective

2. Clean / replace air

nozzle

Fault

Spray pattern irregu-

lar with drips

Cause

Solution

1. Defective nozzle 1. Replace nozzle. Contact

a respective service centre.

2. Paint too viscous 2. Lower viscosity
3. Insufficient

working pres-

sure

3. Increase working pres-

sure (if necessary, not in-

cluded accessories, e.g.

pressure reducer)

3. Hose defective; replace

hose

Fault

Non-uniform paint

amount delivered

Cause

Solution

Nozzle dirty /

defective

Clean / replace air nozzle