Operation, Start the engine, Storing the engine – Parkside PSE 2800 A1 Benutzerhandbuch

Seite 29: Overload protection 2 x 230 v sockets, Cleaning

Advertising
background image

29

GB

Safety instructions / Before use

… / … / Cleaning, maintenance, storage, transport and ordering replacement parts

connector

4

of the generator (fig. C / Pos. 4)

and from the other side to an external ground.

Operation

ATTENTION! When being used for the first

time, motor oil (15 W-40, approx. 0.6 l) and petrol
(unleaded normal petrol) must be put in.

Check the fuel level and the oil, and if necessary
top them up.

Make sure you have adequate ventilation.

Ensure that the spark cable is securely in the
spark plug.

Unplug any electric device connected to the
generator.

Start the engine

ATTENTION! When starting with the express

start

13

you can injure your hand with the sudden

kick back.

Wear protective gloves when starting.

Open the petrol tap

14

by turning the tap down-

wards.

Put the on / off switch

11

to the on position.

Turn the choke lever

12

to I Ø I (in the left

position).

Start the engine with the express start

13

by

sharply pulling the handle. If the engine has not
started pull the handle again.

Push the choke lever

12

back once the engine

has started (in the right position).

To load the generator

Connect the device to the 230 V∼ socket

3

.

ATTENTION! This socket can be loaded con-

tinuously (S1) with 2600 W and short term (S2) for
a maximum of 2 minutes with 2800 W.
Note: Some electric devices (sabre saws, drills etc.)
can use more electricity when doing heavy duty tasks.

Storing the engine

Before putting away, let the generator run with-
out load so that the device can „cool down“.

Turn the on / off switch

11

to the „OFF“ position.

Close the petrol tap

14

.

Overload protection

2 x 230 V sockets

WARNING! This generator is fitted

with an overload protector.
This cuts off the sockets

3

. By activating the over-

load switch

6

the sockets

3

can be used again.

ATTENTION! If this happens reduce the

amount of electrical output which you are
extracting from the generator or remove
defective devices which are attached.

ATTENTION! Faulty overload switches

should only be replaced with identically
constructed overload switches with the
same performance data. Please use our
customer service department.

Cleaning, maintenance,

storage, transport and

ordering replacement parts

Before cleaning and maintenance work, turn off the
engine and pull the spark plug connector

29

out of

the spark plug

28

.

ATTENTION! Turn the device off imme-

diately and contact your Service Station:
- With unusual vibrations or noises.

-

If the engine seems overloaded or has backfired.

Cleaning

Keep the safeguards, air vents (fig. B / Pos. B1)
and the engine housing as dust and dirt free as
possible. Wipe the device with a clean cloth or
blow it with compressed air with low pressure.