REAR VIEW

RS-232 INTERFACE

The RS-232 interface is for connecting media control systems as well as

building management systems providing control and monitoring of all

parameters. Communication is established via an easily to implement ASCII-

protocol allowing trouble-free integration of Remote Amplifiers in media and

touch panel control systems. For a programmer’s guide and complete protocol description, please re-
fer to the documentation accompanying the IRIS software

.

ADDRESS

The address selection switch allows setting the amplifier’s network address,

which, within a CAN-network, can range from 01 to 250 (FA hex). Caution:

Each address may exist only once within a network. Otherwise network

conflicts might occur. Address setting has to be performed in hexadecimal

code. The selection switch LOW represents the low-value digit while the

HIGH-switch represents the high-value digit

.

Adress-Table:

HIGH

LOW

Adress

HIGH

LOW

Adress

0

0

Stand-alone

8

0 ... F

128 ... 143

0

1 ... F

1 ... 15

9

0 ... F

144 ... 159

1

0 ... F

16 ... 31

A

0 ... F

160 ... 175

2

0 ... F

32 ... 47

B

0 ... F

176 ... 191

3

0 ... F

48 ... 63

C

0 ... F

192 ... 207

4

0 ... F

64 ... 79

D

0 ... F

208 ... 223

5

0 ... F

80 ... 95

E

0 ... F

224 ... 239

6

0 ... F

96 ... 111

F

0 ... A

240 ... 250

7

0 ... F

112 ... 127

F

B ... F

reserved

Address 0 (00 hex, factory-pre-set) ensures that the amplifier is separated from the remote
communication, so that it does not appear in the system set-up even though it might be connected
to the CAN-bus. When the amplifier is powered-on with its address set to “0”, all internal parameters
are set to “0” respectively to bypass and the routing is set to 2-in-2. In that case the amplifier behaves
absolutely linear, i.e. signal processing is deactivated

.

REMOTE CAN BUS

Each amplifier employs two RJ-45 sockets for Remote CAN-bus connection.

The sockets are parallel connected and serve as input as well as for

connecting through of the Remote network. Common RJ-45 patch

cables can be used for rack-shelf cabling. The CAN-bus needs to be

terminated at both ends using a 120ohms termination plug. Detailed

guidelines concerning cabling and bus length are provided in the chapter

“REMOTE CONTROL NETWORK”.

Both RJ-45 sockets additionally carry the balanced audio monitor signal.

The nominal output level is +6dBu (1.55V) while the maximum output level is +21dBu (8.7V).


Connector Pin-Assignment:

(View of Contacts)