6 Troubleshooting

Type of malfunction

Possible causes

Correction

Drops form on the trigger

– The needle gasket 5 is

worn respectively loose
and must slightly be
retightened.

• For that purpose

remove needle/valve
cartridge, see
section 4.3. Then
unscrew screw at the
valve body 4 and take
out needle driver
(squared bolt). Using a
small screw driver turn
stuffing box 6 gently
clockwise and try if
needle is sliding
smoothly again within
the tightened gasket.

Drops form on the nozzle

– Either needle or nozzle

is worn.

– Needle is not closed

properly e.g. because
of particle residues
within nozzle.

• Replace needle or

nozzle.

• Clean the needle/valve

cartridge with solvent,
see section 5.

There is an uneven and
not steady spray jet

– Dirt residue within air

cap.

– Nozzle is not correctly

screwed in.

• Clean air cap with

solvent.

• Make sure that nozzle

is screwed in tight.

Air blowing constantly
although trigger is
released.

– O-ring 9 and/or

washer 10 worn.

– Needle nuts are not

counter-screwed in
correct position, see
section 5.3.

• Change O-ring and/or

washer.

Drops form on the
extension at the applicator
and/or the spray head.

– O-rings are worn.

• Change O-rings, see

section 7.2.