Appendices, Technical characteristics – MGE UPS Systems 1500 Rack Benutzerhandbuch

Seite 30

Advertising
background image

34007117EN/AB

- Page 29

6. Appendices

Technical characteristics

(1) The upper and lower thresholds may be set using the UPS Driver software.
(2) Or 40 Hz in low-sensitivity mode (may be set using the UPS Driver software).
(3) Adjustable from 200 to 240 V using the UPS Driver software.

Output rating

AC-input power

Voltage

Frequency

Output power (operation
on battery power)

Voltage

Frequency

Battery (sealed lead-acid,
maintenance free)

Tower models

Rack models

Environment

Noise level (operation on

AC-input power)

Operating temperature

Relative humidity

(without condensation)

Pulsar Evolution

500

500 VA / 350 W

2 x 6 V - 9 Ah,

1100 / 1100 rack

1100 VA / 700 W

2 x 12 V - 9 Ah,

4 x 6 V - 9 Ah

800 / 800 rack

800 VA / 560 W

2 x 12 V - 7.2 Ah,

4 x 6 V - 7.2 Ah

1500 / 1500 rack

1500 VA / 1000 W

3 x 12 V - 9 Ah,

6 x 6 V - 9 Ah

Single-phase, 160 V to 294 V

(1)

, 230V nominal.

Single-phase, 230 V

(3)

(+ 6% / - 10%)

50/60 Hz +/- 0.1 Hz

<40 dBA

0 to 35

°

C

20 to 90%

<40 dBA

0 to 40

°

C

20 to 90%

47 Hz to 70 Hz (50 Hz system) or 56.5 Hz to 70 Hz

(2)

(60 Hz system)

Advertising
Dieses Handbuch ist für die folgenden Produkte bezogen werden: