Emergency run operation, Air flow direction adjustment procedure, Air scroll – MITSUBISHI ELECTRIC SKM35ZD-S Benutzerhandbuch

Seite 11: Swing flap

Advertising
background image

– 10 –

Air scroll

Flap moves up and down
continuously.

• If the room temperature control (thermostat) switches to the heating mode or if the defrosting operation is on, the blow flap changes automatically to a horizontal

position.

• If the heating operation has just started and the room temperature is still low, it may take a while before the flap moves to the above sway operation angle.

• The flap may stop at the tilted down-blow position during the “sway operation” in the heating mode.

NOTE

MEMORY FLAP (FLAP STOPPED)

Adjusting left/right air flow direction

CAUTION

Please stop the air conditioner when
adjusting the air flow direction.

When you press the AIRFLOW button once while the flap is operating, it stops swinging at an
angle.Since this angle is memorized in the micro-computer, the flap will automatically be set at this
angle when the next operation is started.
• Recommended angle of the flap when stopping

Emergency run operation

• The ON/OFF button on the unit operates ON/OFF temporarily when the remote control is not used.

Operation program
• OPERATION MODE :

AUTO

• FAN SPEED

:

AUTO

• AIR FLOW

:

AUTO

• Operation starts by pressing the ON/OFF button; it stops if you press the button again.

Unit ON/OFF button

DANGER

• Avoid constant airflow to the body for hours on end.

CAUTION

• When in COOL or DRY operation, do not operate for hours on end with the air

flow blowing straight down. Otherwise, condensation may appear on the outlet
grill and drip down.

• Do not try to adjust the flaps by hand, as the control angle may change or the flap

may not close properly.

Air flow direction adjustment procedure

HEAT

(Horizontal

blowing)

(Slant forward

blowing)

COOL, DRY

Adjust the direction by moving the left/right
air flow fin by hand.

SWING FLAP

Thick line

: moves quickly

Thin line

: moves slowly

Thick line

: moves quickly

Thin line

: moves slowly

Stops at this position
for 5 seconds.

Stops at this position
for 5 seconds.

In COOL and DRY operation

In HEAT operation

Adjusting up/down air flow direction

■ Up/down direction can be adjusted with the AIRFLOW button on the remote control. Each time when you press this button the mode changes

as follows:

Change to AIRFLOW mode.

(Air scroll)

(SWING)

(flap stopped)

RWA012A226C_En