34

Trouble-shooting

Many problems have a simple cause and a correspon-
dingly simple solution. The following section describes a
few difficulties you may encounter, and the measures
you need to take to cure them.

If you find it impossible to solve a problem with the help
of these notes please ask your authorised

 specialist

dealer for advice.

Problem:

No output signal, or seriously distorted
signal at the loudspeakers.

Cause:

Short-circuit at the loudspeaker cables;
e.g. through stray wire strands at the ter-
minal clamps, or mechanical damage to
the cables.

Remedy:

Check loudspeaker cables and terminals
carefully, twist wire ends neatly (conductor
sleeves can also be used); be sure to
replace damaged cables!

Problem:

Flat sound image, insufficient bass res-
ponse.

Cause:

The loudspeaker cables are connected
with reversed polarity.

Remedy:

Check the speaker connections at the
loudspeakers and at the amplifier’s spea-
ker terminals, referring to the wiring dia-
gram; correct if necessary.

Problem:

Excessive or booming bass response.

Cause:

The loudspeaker is set up too close to the
wall or in one corner of the room.

Remedy:

Maintain a minimum distance of 50 cm to
the side walls, or change the setting of the
„BASS“ switch on the back of the speaker.

Cause:

Sympathetic vibration of floor, room walls
or furniture.

Remedy:

Use spikes or damping elements to suit
your installation. Ask your specialist

dealer for advice.

Problem:

No treble response from the TCI 1 RE or
TCI 2 E.

Cause:

The high voltage for the electrostatic treble
units is not present.

Remedy:

Move the mains switch on the back of the
speaker to the „ON“ position.

Advertising