Instructions for the installer, Electrical connection, Connecting the terminal board – Zanussi ZOU235X Benutzerhandbuch

Seite 53: Electrical connection with the hob

Advertising
background image

Electrolux

53

Instructions for the Installer

The instructions given below are

designed specifically for a qualified

installer and should aid him or her to

perform all installation, adjustment, and

maintenance operations with absolute

precision and in compliance with all

current legislation and regulations. We

strongly recommend that all

operations for the installation of your

cooker be carryed out by Qualified Per-

sonnel in accordance with existing

rules and regulations.

Electrical connection

Prior to making the electrical connection, make sure that:

— the protection fuse and the domestic wiring

system are suitable to carry the total electric load of

the oven (see rating plate);

— your domestic wiring system has an

efficient earth connection in compliance with rules

and laws in force;

— the wall socket or the omnipole switch used

for the electrical connection can easily be reached

after the oven is built in.

This appliance is delivered without an electric supply

cable, therefore, you will have to fit to it a supply cable

with standard plug, suitable for the total electric load

shown on the rating plate. The plug is to be inserted into

a suitable wall socket. If you require a direct connection

to the electric network (mains), it will be necessary to fit

between the appliance and the mains an omnipole

switch, with a minimum gap between contacts of 3 mm,

suitable for the required load and in compliance with

rules in force. The green & yellow ground wire must

not be interrupted by the switch, and should be 2-3 cm

longer than the phase and neutral wires. The supply

cable must in all cases be laid out in such a way as to

ensure that it does not reach at any given point a

temperature 50°C higher than the ambient

temperature.

Suitable power supply cables are the following types,

considering the respective necessary section of cable:

H07 RN-F, H05 RN-F, H05 RR-F, H05 VV-F, H05

V2V2-F (T90), H05 BB-F.

Connecting the terminal board

The appliance incorporates an easily accessible 6-pole

terminal board whose jumpers (bridges) are already

pre-set for operation on 400 V tri-phase with neutral wire

(Fig. 12). In case a different mains voltage is present, the

jumpers on the terminal board must be rearranged as

shown in the diagram (Fig. 13). The ground cable must be
connected to terminal

. After connecting the supply

cable to the terminal board, secure it with a junction clamp.

Electrical connection with the hob

This oven can be connected to hobs indicated in the

paragraph "Technical data". The socket for

connecting the hob is located at the top of the oven

cabinet. The hobs come complete with connecting

leads for the hot plates/heat areas and ground cable;

these leads feature plug-in connectors. Connection of

the hob to the oven is carried out by plugging-in these

connectors to the corresponding oven socket.

The plug-to-socket connection design is such as to

prevent possible wrong plugging-ins.
The Manufacturer disclaims any liability in case

these accident-preventing rules are not

observed.

230V 3~

1 2 3 4 5

L1 L2 L3 PE

230V 1~

1 2 3 4 5

L1 N PE

400V 2N~

1 2 3 4 5

L1 L2 N PE

400V 3N~

1 2 3 4 5

L1 L2 L3 N PE

Ø 4x2,5mm²

Ø 3x2,5mm²

Ø 4x2,5mm²

Ø 5x1,5mm²

Fig. 12

Fig. 13

Advertising