Instructions for the Installer

The instructions given below are

designed specifically for a qualified

installer and should aid him or her to

perform all installation, adjustment, and

maintenance operations with absolute

precision and in compliance with all

current legislation and regulations. We

strongly recommend that all

operations for the installation of your

cooker be carryed out by Qualified Per-

sonnel in accordance with existing

rules and regulations.

Electrical connection

Prior to making the electrical connection, make sure that:

— the protection fuse and the domestic wiring

system are suitable to carry the total electric load of

the oven (see rating plate);

— your domestic wiring system has an

efficient earth connection in compliance with rules

and laws in force;

— the wall socket or the omnipole switch used

for the electrical connection can easily be reached

after the oven is built in.

This appliance is delivered without an electric supply

cable, therefore, you will have to fit to it a supply cable

with standard plug, suitable for the total electric load

shown on the rating plate. The plug is to be inserted into

a suitable wall socket. If you require a direct connection

to the electric network (mains), it will be necessary to fit

between the appliance and the mains an omnipole

switch, with a minimum gap between contacts of 3 mm,

suitable for the required load and in compliance with

rules in force. The green & yellow ground wire must

not be interrupted by the switch, and should be 2-3 cm

longer than the phase and neutral wires. The supply

cable must in all cases be laid out in such a way as to

ensure that it does not reach at any given point a

temperature 50°C higher than the ambient

temperature.

Suitable power supply cables are the following types,

considering the respective necessary section of cable:

H07 RN-F, H05 RN-F, H05 RR-F, H05 VV-F, H05

V2V2-F (T90), H05 BB-F.

Connecting the terminal board

The appliance incorporates an easily accessible

6-pole terminal board whose jumpers (bridges) are

already pre-set for operation on 400 V tri-phase with

neutral wire (Fig. 5). In case a different mains voltage is

present, the jumpers on the terminal board must be

rearranged as shown in the diagram (Fig. 6). The
ground cable must be connected to terminal

. After

connecting the supply cable to the terminal board,

secure it with a junction clamp.

230V 3~

1 2 3 4 5

L1 L2 L3 PE

230V 1~

1 2 3 4 5

L1 N PE

400V 2N~

1 2 3 4 5

L1 L2 N PE

400V 3N~

1 2 3 4 5

L1 L2 L3 N PE

FO 0330

Ø 4x2,5mm²

Ø 3x2,5mm²

Ø 4x2,5mm²

Ø 5x1,5mm²