Technical data, Table 2, Table 3 – Teka VR 90 4G AI TR AL Benutzerhandbuch

Seite 20

Advertising
background image

GB

20

Technical data

COMMON FEATURES FOR ALL MODELS
WITH ELECTRIC HOTPLATES AND AUTO-
MATIC IGNITION

The supply voltage and frequency will be
as shown on the rating plate.

If an electric hotplate gets cracked, the
hob should be disconnected from the elec-
tricity current.

COMMON

FEATURES

FOR

ALL

MODELS WITH GAS BURNERS

Warnings:

a) Before installation, make sure that the
local supply conditions (the gas type and
pressure) are compatible with the applian-
ce’s setup.
b) The setup conditions for this appliance
are written on the label (or the rating
plate).
c) This appliance should not be connected
to a device for removing combustion
products. It should be installed and con-
nected in compliance with the current ins-
tallation standards. Special attention
should be paid to the regulations applying
to ventilation.

A gas cooking appliance produ-

ces heat and moisture at the site where
it is installed. The kitchen should be
provided with suitable ventilation: natu-
ral ventilation sources should be kept
clear, a window opened, or an effective
mechanical ventilation system device,
such as a hood, installed.

The intense and prolonged use

of the appliance may call for comple-
mentary ventilation, such as opening a
window, or more efficient ventilation
such as increasing the power of the
mechanical ventilation if this exists.

Class 3 Hob.

You should keep the Guaran-

tee Certificate or, where relevant, the
technical datasheet, together with
the Instruction Manual for the dura-
tion of the useful life of the appliance.
It has important technical information
about the appliance.

Country

France

United Kingdom

Greece

Italy

Category

II2E+3+

II2H3+

I3+

II2H3+

Table 2

CG Lux-60, CG Lux-70,
CGC 4G, CG.1 4G, CG.1 3G 1P

Table 3

Semi-rapid

1,75

0,17

0,19

0,13

0,13

0,47

Burner

Nominal Calorific Consumption

Nominal Consumption*

Auxiliar

1

0,10

0,11

0,07

0,07

0,33

Rapid

3

0,29

0,33

0,22

0,21

0,77

Triple

crown

3,5

0,33

0,38

0,25

0,24

--

s

kW

G-20 (Nm

3

/h)

G-25 (Nm

3

/h)

G-30 (Kg/h)

G-31 (Kg/h)

mbar

20

25

29

37

* Consumption over Gross Calorific Value (H )

Performance

%

CCR CG Lux-75 and CG Lux-86

VR 90 4G, CG Lux-70 5G TR

kW

kW

kW

1,55

1,55

>52

0,77

--

>52

0,33

--

--

0,47

0,47

>52

Advertising