Move the Visualizer into the desired position (fig.8). Once the position has been found, release
the Visualizer (fig.9) and tighten the Allen screws to prevent the unit from detaching and moving
(fig.10).
fig.9
fig.11
fig.12
fig.13
fig.8
All required cables can now be pulled through the opening of the ceiling mount and connected
(fig.11). Move the Visualizer back into the unreleased position (fig.12). Pull and turn the security
lock mechanism counter-clockwise to release it.
Make sure that the folding mechanism is completely closed. You will hear a "click" sound when it
is completely closed. (fig.13).
security lock
mechanism
LOCKED
pull
and
turn
to
unlock
UNLOCKED
fig.10
Mount the stabilization ring with the enclosed Allen screws loosely into the corresponding screw
threads (fig.6). Don’t tighten the Allen screws yet.
Now move the Ceiling Visualizer into unreleased position (fig.7). Pull and turn the security lock
mechanism counter-clockwise to release it.
fig.7
security lock
mechanism
fig.6