Make sure that the temperature in the working area is between +5 and +45 °C.

•

Always observe the existing maintenance program (see 4. in this manual).

•

Do not touch the internal arranged components and pipes. These parts reach a very high
temperature during the operation and keep that for a certain time after switching off.

•

Do not leave inflammable objects or nylon parts or cloths near the vacuum pump.

•

Do not move the vacuum pump with the tank under pressure.

•

Do not use the vacuum pump with the supply cord damaged or with precarious connection.

•

Do not use the vacuum pump in a potential explosive environment (e.g. in the immediate vi-
cinity of gas tanks) or near open flames and never in moist or dusty premises.

•

Do not allow anyone to operate the vacuum pump unless she/he has received correct in-
structions.

•

Do not hit the fan wheels with metallic or sharp objects as they could break during operation.

•

Do not operate the vacuum pump without air filter.

•

Do not alter any manipulations to the safety and adjusting devices.

•

Do not connect a hose which has a flow rate lower than that of the vacuum pump.

2

Technical Data

FF35200

FF35204

Vacuum ................................................ 85 % ..................................... 85 %

Suction volume ..................................... 200 l/min ............................... 200 l/min

Motor speed range ................................ 2850 1/min ............................ 3520 1/min

Motor power.......................................... 1,1 kW .................................. 1,1 kW

Voltage ................................................. 230 V / 50 Hz ........................ 110 V / 60 Hz

Pressure tank volume ........................... 10 l ....................................... 10 l

Vacuum pump ...................................... oilfree ................................... oilfree

Weight .................................................. ca. 20 kg ............................... ca. 20 kg

Class of protection ................................ I ............................................ I

Protection type ...................................... IP 22 ..................................... IP 22

Typical A-rated sound level:

Noise pressure level (L

pA

) .................... 77 dB (A) | K

pA

3 dB (A) ........ 77 dB (A) | K

pA

3 dB (A)

Sound power level (L

WA

) ...................... 88 dB (A) | K

WA

3 dB (A) ........ 88 dB (A) | K

WA

3 dB (A)

The noise level during operation can exceed 85 dB (A). Wear hearing protection!

Measured values determined in accordance with EN 61029-1:2010.

3

Function of the Unit

3.1

Initial operation

The place should be free of dust and color fog, well-tempered and opened for fresh
air. Do not place the vacuum pump near a heating or directly in the sunlight. In order
to ensure proper ventilation, the vacuum pump shall be positioned at least at 50 cm
from any obstacles. Select a dry and horizontal surface and prevent it from movement!

Before the setup of the machine you have to check the following points!
•

The surface for a low-pressure mounting must be not porous and must be flat and free of
cracks. This kind of mounting can't be use, if this is not the case.

•

Check the voltage, frequency and tension mentioned and compare with you own at side.

•

If the motor will not start within 5 seconds after switched on, you have to pull out the plug
immediately, motor and compressor to be checked carefully. The vacuum pump could be
blocked in such a case.