9 technical data, 1 electrical data, 2 mechanical data – Baumer HEAG 176 Benutzerhandbuch
Seite 13: Technical data, Electrical data, Mechanical data

MB006
heag171-176_mb (13A1)
10
9.1
Electrical data
•
Transmission length: ≤300 m
HEAG 171
•
Voltage supply:
9...26 VDC
5 VDC ±5 %
•
Consumption:
≤200 mA
•
Inputs:
4 x TTL
•
Input signals:
K1, K2, K3, K4 + inv.
•
Outputs:
4 x fiber optic
•
Output signals:
Fiber optic 1, 2, 3, 4
HEAG 172
•
Voltage supply:
9...26 VDC
•
Consumption:
≤200 mA
•
Inputs:
4 x HTL
•
Input signals:
K1, K2, K3, K4 + inv.
•
Outputs:
4 x fiber optic
•
Output signals:
Fiber optic 1, 2, 3, 4
HEAG 173
•
Voltage supply:
5 VDC ±5 %
•
Consumption:
≤60 mA
•
Inputs:
3 x fiber optic
•
Input signals:
Fiber optic 1, 2, 3
•
Outputs:
3 x TTL
•
Output signals:
K1, K2, K3 + inv.
HEAG 174
•
Voltage supply:
9...26 VDC
•
Consumption:
≤60 mA
•
Inputs:
3 x fiber optic
•
Input signals:
Fiber optic 1, 2, 3
•
Outputs:
3 x HTL
•
Output signals:
K1, K2, K3 + inv.
HEAG 175
•
Voltage supply:
9...26 VDC
5 VDC ±5 %
•
Consumption:
≤200 mA
Technical data
9
•
Inputs:
3 x TTL
•
Input signals:
K1, K2, K3 + inv.
•
Outputs:
3 x fiber optic
•
Output signals:
Fiber optic 1, 2, 3
HEAG 176
•
Voltage supply:
9...26 VDC
•
Consumption:
≤200 mA
•
Inputs:
3 x HTL
•
Input signals:
K1, K2, K3 + inv.
•
Outputs:
3 x fiber optic
•
Output signals:
Fiber optic 1, 2, 3
9.2
Mechanical data
HEAG 171, HEAG 172
•
Dimensions
W x H x L:
122 x 122 x 80 mm
•
Protection:
IP 65 IEC 60529
•
Operating
temperature:
-20...+70 °C
(without dew)
•
Connection:
3x cable gland
M20x1,5
4x cable gland
M16x1,5
HEAG 173, HEAG 174, HEAG 175,
HEAG 176
•
Dimensions
W x H x L:
50 x 75 x 55 mm
•
Protection:
IP 20 IEC 60529
•
Operating
temperature:
-20...+50 °C
(without dew)
•
Connection:
3x screw terminal
connector
Connector (VL, ST
or SMA)
9
Technical data