8. Operating plan
Line Default Settings
Description Outline
01 0
F1 - Tacho Display F1
02 0
F2 - Tacho Display F2
03 0
F3 - Tacho Display F3
04 0
SZ – Dragging Value
05 1 0 0 0
P1 - Limit Value 1
06 2 0 0 0
P2 - Limit Value 2
10 - - - - - -
Separating
Line
11 S t a t 0
F1 - Status for Tacho Display F1
12 S t a t 0
F2 - Status for Tacho Display F2
13 S t a t 0
F3 - Status for Tacho Display F3
14 S t a t 0
SZ - Status for Dragging Value
15 S t a t 0
P1 - Status for Limit Value 1
16 S t a t 0
P2 - Status for Limit Value 2
20 - - - - - -
Separating
Line
21 2 1 0
Calculating
Function
22 2 2 0
Inversion of Calculating Function
23 2 3 0
Count Mode Tacho 1
24 2 4 0
Input
Logic
25 2 5 b F 1
Evaluation Tacho F1
1.0 0 0 0
26 2 6 b F 2
Evaluation Tacho F2
1.0 0 0 0
27 2 7 b F 3
Factor for Calculating Function F3
1.0 0 0 0
28 2 8 1
Update-Time
F1,F2,F3
29 2 9 0
Time-out
F1,F2,F3
30 3 0 0
Time Unit Tacho F1
31 3 1 0
Time Unit Tacho F2
32 3 2 0
Assignment Dragging Value
33 3 3 0
Assignment Digital Output 1
34 3 4 0
Assignment Digital Output 2
35 3 5 0
Output Logic of Digital Outputs
36 3 6 0
Decimal Point F1
37 3 7 0
Decimal Point F2
38 3 8 0
Decimal Point F3
39 3 9 0
Selection Basic Display
40 4 0 C o d
Code
0
41 4 1 0
Assignment Function Key
42 4 2 0
Output Reaction Lower Limit Value
51 5 1 0
Baud
rate
52 5 2 0
Parity
53 5 3 0
Stop
Bits
54 5 4 0
Address
61 6 1 0
Analog Output Assignment
62 6 2 0
Offset for Analog Output
63 6 3 u A
Lower Analog Value
0
64 6 4 o A
Upper Analog Value
4 0 9 5
65 - - - - - -
Separating