7. Overview on control tokens applied

Control

token

Hex

Decimal

<STX>

02

02

<ETX>

03

03

<ACK>

06

06

<LF>

0A

10

<CR>

0D

13

<DC1>

11

17

<CAN>

18

24

<DEL>

7F

127


8. Operating plan

Line Default

Firmware

Short

explanation

01

0

XP – current value main counter

02

1 0 0

P1 - preset 1

03

1 0 0 0

P2 - preset 2

04

0

SC – start count value

05

0

Σ -

totalizer

06

0

§ - hour counter

07

1.0 0 0 0

SF – scaling factor

10

- - - - - -

Separating line

11

S t a t 0

S t a t

XP – current value main counter

12

S t a t 0

S t a t

P1 - preset 1

13

S t a t 0

S t a t

P2 - preset 2

14

S t a t 0

S t a t

SC – start count value

15

S t a t 0

S t a t

Σ - current value main counter

16

S t a t 0

S t a t

§ - current value main counter

17

S t a t 0

S t a t

SF – scaling factor

20

- - - - - -

Separating line

22

2 2 0

2 2

Operating modes

24

2 4 0

2 4

Decimal point

25

2 5 0

2 5

Count mode

26

2 6 0

2 6

Frequency main counter track A

27

2 7 0

2 7

Frequency main counter track B

28

2 8 0

2 8

Input logic

29

2 9 0

2 9

Main counter reset (control input 1)

31

3 1 0

3 1

Functionality control input 2

33

3 3 0

3 3

Output logic of digital output

35

3 5 t 1

3 5

Output time P1

0.2 5

36

3 6 t 2

3 6

Output time P2

0.2 5

37

3 7 0

3 7

Adopt presets P1,P2

38

3 8 0

3 8

Value range P1,P2 and SC

39

3 9 0

3 9

Function key assignment

40

4 0 C o d

4 0

Code

0

41

4 1 0

4 1

Batch counter functiopn

42

4 2 1

4 2

Batch counter multiplier

43

4 3 C o r

4 3

Offset

0

42

4 4 0

4 4

Display power loss

51

5 1 0

5 1

Baud rate

52

5 2 0

5 2

Parity