Esc " ⁄ " n "data" cr or lf, Esc dc3 n – Citizen Systems iDP3550 Benutzerhandbuch

Seite 104

Advertising
background image

iDP3550/3551 User’s Manual

88

CITIZEN

ESC "

" n "data" CR or LF

[Function]

Defining the message

[Code]

<1B>H <2F>H n "data" CR or LF

[Range]

1

n

10

[Outline]

This command can define up to a 50-byte message in one line.

If the value of n is

specified beyond the range, the data following n will be treated as the print data.

Once the message is defined, it remains valid until it is redefined.

The data should end

with CR (0DH) or LF (0AH).

If the data exceeds 50 bytes, the subsequent data will be

treated as the print data.

Once the message is defined, it remains valid until it is redefined or the download deletion

command (ESC DC2 n1 n2) is executed.

ESC DC3 n

[Function]

Printing the message

[Code]

<1B>H <13>H n

[Range]

1

n

10

[Function]

This command prints a message.

If the value of n is specified beyond the range or if

nothing is specified to n, the messag e will not be printed.

Advertising