3 inputandoutputsignals, 1 inputandoutputsignals, Input and output signals – Citizen Systems iDP3550 Benutzerhandbuch

Seite 50

Advertising
background image

iDP3550/3551 User’s Manual

34

CITIZEN

10.3

Input and Output Signals

10.3.1

Input and Output Signals

(1) RXD

This is a serial received data signal.

When a framing error, overrun error, or parity error occurs,

that data is printed as "?".

(2) DTR

When this signal is Ready, write the data or a command.

If written at the time of Busy, an overrun

error results, ignoring the previous data.

The data can be written in the input buffer even during

printing.

Busy is also issued at the time of power -on, test print, on-line, and reset.

(3) TXD

XON (11H) or XOFF (13H) is sent at XON/XOFF control.

XON (11H) is sent every 3 seconds in

the Star mode.

When a command is received, that requests the printer state and printer status, 1-byte corresponding

data is output.

(4) DSR

When this signal is a space, the data is sent from the printer side.

Note that if this signal is a mark

when a request to send command is executed, the printer will wait until the signal becomes a space.

(5) FAULT

CBM mode

When this signal is Space, a mechanical error has occurred.

Star mode

When this signal is Mark, a mechanical error has occurred.

(6) RESET

A signal to reset the entire printer. (Active Low)

(7) RTS

This signal is turned to Space when the printer is turned on.

Advertising
Dieses Handbuch ist für die folgenden Produkte bezogen werden: