8 Technical data GigaSystem 17/X (guaranteed parameters)
2) All other trunk lines have a signal .
42
GB
Switching matrices
Model
GigaSystem17/8 G
GigaSystem17/8 K
Application
for 8 participants
for 8 participants
Terr:47..862GHz,Sat: 0,95..2,15GHz
Terr.
Sat.
Terr.
Sat.
Trunk line gain
-2 ... -3dB
-2 ... -4dB
Slope correction
none
Tap gain: Corresponds to participant’s
gain in switching matrices
-4 ... -1dB -2 ... +1dB
1 ... 4dB
-2 ... +1dB
Slope correction
fixed correction
Return loss
Trunks
Taps
10dB
8dB
Isolation
Trunks 2)
Taps
45dB
35dB
Input level
recommended
maximum
72 dBμV 3)
70 dBμV 4) 75 dBμV 3)
As for17/8G
80 dBμV
85 dBμV
85 dBμV
Power supply
for unit
for LNB’s
Power supply 18V, 13V
total <2,2A, (overload &
short-circuit protected)
17/8G: Standby (Terr.aktiv) <3W
feed from
17/8G bzw. GR
18V, 13V, High-Band SAT1 with 22kHz (only for 17/8 G und K)
DC resistance of unit for one voltage
<100mOhm (one line has
300mOhm)
Power consumption from power supply3)
from receiver
70mA (from 18V)
130mA (from 18V)
40mA, max. 240mA (current pool)
Control via receivers
DiSEqC 1.0 or higher,
„Mini“-DiSEqC (receives only SAT1 und 2) or
11,5V ... 14V/16V ... 19V a. 0/22kHz, USS >0,25V (only SAT1)
Screening level
in accordance with EN50083-2/A1 and TechniSelect S
Ambient conditions
-25 ... +55°C,
overvoltage protection inputs, outputs < 5kV
Dimensions: L x W x H, weight
275 x 175 x 56; 1kg
154 x 175 x 48; 0,8kg
Article number
0000/3271
0000/3272