TechniSat GigaSystem 17/8 K Benutzerhandbuch
Seite 43

3) Related to broadband cable signal in BC grid (36 TV signals, 14 FM programmes), CTB
(72 dB) / CSO (69 dB), with terrestrial reception individual channels are usually
stronger,this is acceptable as long as they remain <90 dBμV.
4) in accordance with EN 50083-3: IMA3 35 dB
43
GB
Accessories
Model
Intermediate ampli-
fier 17Z
Active branch dis-
tributor17/2A
Passive distributor
17P
Application
Amplification,
when the level is drop-
ped down
spared branching of
two side trunks
signal split-
ting
Terr:47..862GHz,Sat: 0,95..2,15GHz
Terr.
Sat.
Terr.
Sat.
Terr.
Sat.
Trunk line gain
5 ... 10dB,
adjustable
7 ... 12dB
-1.2dB
-1 ... -1.5dB
Slope correction
fixed correction
none
Tap gain Corresponds to partici-
pant’s gain in switching matrices
5dB,
adjustable
3 ... 6 dB
-4dB
-4dB
Slope correction
adjusta-
ble
fixed cor-
rection
none
Return loss
Trunks
Taps
10dB
14dB
8dB
10dB
Isolation
Trunks 2)
Taps
40dB
50dB, widely cascadable
45dB
45dB
Return path loss
Trunk
5 ... 30 MHz, only R-types
Taps
1.5dB
2dB
4.5dB
11dB
Input level
recommended
maximum
58 dBμV
55 dBμV
65 dBμV
70 dBμV
passive
75 dBμV
70 dBμV
75 dBμV
85 dBμV
Power supply
for unit
for LNB’s
via the trunk lines
from a 17/8G-opwer
supply
in the side trunks
not needed, passive
from a unit with
power supply
in the main trunk
via one direct current
path
DC resistance of unit for one
voltage
< 50mOhm (one line has 130mOhm)
< 50mOhm
Power consumption from power supply3)
from receiver
180mA (18V),120mA
(13V)
300mA (von 18V)
Screening level
in accordance with EN50083-2/A1 and TechniSelect S
Ambient conditions
-25 ... +55°C, overvoltage protection inputs, outputs < 5kV
Dimensions: L x W x H, weight
212 x 58 x 45; 0,7kg
212 x 105 x 45; 1,3kg
212 x 69 x 45; 0,9kg
Article number
0000/3269
0000/3270
0000/3268
GigaSystem_17_8_deu_engl_23112011_3.qxp 28.11.2011 09:34 Seite 43