7 error search assistance – TechniSat TechniLAN 4/4 Active Benutzerhandbuch

Seite 16

Advertising
background image

16

EN

MONT_TechniLAN_4_4_aktiv_DE_EN.doc 04.09.2012 09:51 Seite 16

Power Consumption
(without sockets and
distribution technology)

max. 400 mA

type 250 mA

Dimensions: L x B x H (mm),
Weight

121 x 114 x 33, 240 g

7 Error Search Assistance

Error Possible

Causes Help

The data rate is too low.

• Inputs and outputs of the

TechniLAN 4/4 active have
been switched.

• The dampening between the

TechniLAN 4/4 aktiv and the
socket is too effective

• Check whether or not the device is

correctly connected with the multi-
switch and/or the LNB.

• Check the cabling.

The green power LED
of a participant socket
does not light up.

A short circuit has occurred
between the participant socket and
the TechniLAN 4/4 aktiv.

• Check the cabling.

The power LED of the
TechniLAN does not
light up

The wall power supply switched off
due to overloading

• Check the cabling for short circuits.
• Connect a separate wall power

supply with the multi-switch.

The yellow traffic LED of
the participant socket
does not light up.

Up to now, no successful LAN
connection could be established via
the coaxial cable

• Wait a few seconds, establishing a

connection might take a few minutes.

• Check the cabling.

Connected receivers
signal short circuits
within the LNB cable for
specific programs

The receiver is not capable of
supplying the TechniLAN socket as
well as the distribution system with
enough power, especially when
selecting programs from the
horizontal polarization (18 V).

• Connect a separate wall power

supply with the multi-switch.







Your device is CE approved and meets all necessary EU standards.