The following jumpers are available for individual settings:
1.

„Buz.“ (on/off) ... Default setting: „on“

2.

„Err.“ (perm./all) ... Default setting: „all“

General

Jumper

1. „Buz.“ jum-
per

-

„on“ position ... A buzzer (acoustic signal)
sounds if a service code is signalled. Soun-
ding the acoustic signal also switches the
relay.

2. „Err.“ jum-
per

A. Temporary service codes:

These service codes only appear temporarily and prevent feeding
into the grid for a short time.
Example: Deactivation due to fluctuations in the mains voltage

-

The Fronius Signal Card reacts if a temporary service code occurs
more than 50 times in a single day.

B. Permanent service codes:
-

Service codes that concern at least one fault in the inverter and cau-
se it to stop (e.g. hardware fault).

-

The Fronius Signal Card reacts if a permanent service code is sig-
nalled for longer than 4:15 hours.

-

„off“ position ... Only the relay is switched if
a service code is signalled. An additional
acoustic signal is not emitted.

Buz.

off

on

Buz.

off

on

-

„all“ position ... Every service code (perma-
nent or temporary) causes the relay to
switch or the buzzer to sound.

-

„perm“ position ...Only permanent service
codes cause the relay to switch or the buz-
zer to sound.

Err.

perm.

all

Err.

perm.

all