B Service instructions
Repair of defects
Defect
Reparation
The appliance does not work at all (you can not
hear any noise from the ventilator)
Exchange 16 Ampere fuse of the appliance
The bulb of the appliance does not shine, but
electronics are working, i.e. motors are working
1. The bulb is defect and you have to change it
2. The temperature switch of the appliance is
released. Plug out your Varyscan
®
and after
approximately 15 minutes plug it in again. Check
now, if both ventilators are working and if they are
clean. If one of the ventilators is defect, have it
exchanged by a specialist or the producer. If the
scan turns off again and again, please contact
your dealer.
DMX-input does not work
Control DIP-switch position