Equipment data, Appendix: 12.2 equipment data – Dimplex SI 9CS Benutzerhandbuch
Seite 14

14
APPENDIX: 12.2 EQUIPMENT DATA
Equipment Data
EQUIPMENT DATA for brine-to-water heat pumps for heating purposes
1
TYPE AND COMMERCIAL DESCRIPTION
..5CS
..7CS
..9CS
..11CS
..14CS
..17CS
..21CS
2
MODEL
2.1
Enclosure type acc. to EN 60 529
IP 20
IP 20
IP 20
IP 20
IP 20
IP 20
IP 20
2.2
Installation site
indoors
indoors
indoors
indoors
indoors
indoors
indoors
3
PERFORMANCE DATA
3.1
Operating temperature limits:
Heating water supply
°C
max. 55
max. 55
max. 55
max. 55
max. 55
max. 55
max. 55
Brine (heat source)
°C
-5 to +25
-5 to +25
-5 to +25
-5 to +25
-5 to +25
-5 to +25
-5 to +25
Antifreeze agent
monoethylene glycol
monoethylene glycol
monoethylene glycol
monoethylene glycol
monoethylene glycol
Minimum brine concentration (-13°C freezing temperature)
0,25
0,25
0,25
0,25
0,25
0,25
0,25
3.2
Heating water temperature spread at B0 / W35
K
10,1
9,9
10,5
10,1
9,6
9,3
11,3
3.3
Heating capacity / coeff.of perform.
at B-5 / W55
1)
kW / ---
3,8 / 1,96
5,6 / 2,2
7,7 / 2,3
9,4 / 2,4
12,5 / 2,6
14,4 / 2,6
17,9 / 2,5
at B0 / W50
1)
kW / ---
4,8 / 2,75
6,7 / 2,9
9,0 / 3,1
11,3 / 3,0
14,2 / 3,4
16,7 / 3,2
20,4 / 3,1
at B0 / W35
1)
kW / ---
5,3 / 4,3
6,9 / 4,3
9,2 / 4,4
11,8 / 4,4
14,5 / 4,5
17,1 / 4,6
21,1 / 4,3
3.4
Sound power level
dB(A)
54
55
56
56
56
58
59
3.5
m³/h / Pa
0,45 / 2000
0,6 / 2500
0,75 / 4500
1,0 / 3500
1,3 / 3500
1,5 / 4000
1,6 / 6000
3.6
Brine flow rate at internal pressure difference (heat source)
m³/h / Pa
1,2 / 6500
1,7 / 10000
2,3 / 16000
3,0 / 13000
3,5 / 1300
0
3,8 / 9000
6,0 / 12000
3.7
Refrigerant; total charge weight
Type / kg
R407C / 1,7
R407C / 1,5
R407C / 1,8
R407C / 2,0
R407C / 2,3
R407C / 2,8
R407C / 4,5
4
DIMENSIONS; CONNECTIONS AND WEIGHT
4.1
Equipment dimensions without connections
4)
H x W x L mm
800
Ч
600
Ч
500
800
Ч
600
Ч
500
800
Ч
600
Ч
500
800
Ч
600
Ч
500
800
Ч
600
Ч
500
1380
Ч
600
Ч
500
1380
Ч
600
Ч
500
4.2
Equipment connections for heating system
inches
thread 1" i/ext.
thread 1" i/ext.
thread 1" i/ext.
thread 1" i/ext.
thread 1" i/e
xt.
4.3
Equipment connections for heat source
inches
thread 1¼" i/ext.
thread 1¼" i/ext.
thread 1¼" i/ext.
thread 1¼" i/ext.
thread 1¼" i
/ext.
thread 1½" i/ext.
4.4
Weight of transport unit(s) incl. packaging
kg
131
133
134
145
157
165
215
5
ELECTRICAL CONNECTION
5.1
Nominal voltage; fusing
V / A
400 / 16
400 / 16
400 / 16
400 / 16
400 / 16
400 / 16
400 / 20
5.2
Nominal power consumption
1)
B0 W35
kW
1,23
1,6
2,07
2,66
3,22
3,72
4,91
5.3
Starting current with soft starter
A
22 (w/out soft st.)
30 (w/out soft st.)
15
26
26
27
29
5.4
Nominal current B0 W35 / cos
ϕ
A / ---
2,22
2,89
3,77
4,84
5,81
6,35
8,86
6
COMPLIES WITH EUROPEAN SAFETY REGULATIONS
3)
3)
3)
3)
3)
3)
3)
7
OTHER DESIGN CHARACTERISTICS
7.1
Water inside equipment protected against freezing
2)
ja
yes
yes
yes
yes
yes
yes
7.2
Performance settings
1
1
1
1
1
1
1
7.3
Controller internal / external
internal
internal
internal
internal
internal
internal
internal
1)
2)
4)
3)
See EC Declaration of Conformity
Subject to technical modifications
Issued 24.03.2004
These
data
characterize
the
size
and
performance
capability
of
the
system.
For
economic
and
energetic
reasons,
additional
factors
such
as
balance
point
and
control
need
to
be
taken
into
consideration.
Abbreviations
have
the
following
meaning,
e.g.
B10
/
W55:
heat
source
temperature
10
°C
and
heating water supply temperature 55 °C.
Heating water flow rate at internal pressure dif
ference
The heating circulating pump and the controller of the heat pump must be ready for operation at all times.
Please keep in mind that morer space is required for pipe connection, operation and maintenance.