READ IMMEDIATELY

1.1 Important Information

The heat pump is not attached to the

wooden pallet.

The heat pump must not be tilted

more than max. 45

°

(in either direction).

Do not lift unit by the holes in the

panel assemblies!

Flush the heating system prior to

connecting the heat pump.

The supplied strainer is to be fitted

in the heat source inlet of the heat pump in order

to protect the evaporator against contamina-

tion.

The brine must contain at least 25 %

of a frost and corrosion protection agent on a

monoethylene glycol or propylene glycol basis.

The clockwise phase sequence

must be observed when connecting the load

line.

Commissioning of the heat pump

must be performed in accordance with the

mounting and operating manual of the heat

pump controller.

1

READ IMMEDIATELY

CAUTION!

CAUTION!

CAUTION!

CAUTION!

CAUTION!

CAUTION!

CAUTION!

Any work on the heat pump may only

be performed by authorised and qualified

customer service technicians.

All power circuits must be dis-

connected from the power source prior to

opening the cabinet.

CAUTION!

1.2 Legal Provisions and Directives

This heat pump conforms to all relevant DIN/VDE

regulations and EU directives. For details refer to

the EC Declaration of Conformity in the appendix.

The electrical connection of the heat pump must be

performed according to and conforming with all re-

levant VDE, EN and IEC standards. Beyond that, the

connection requirements of the local utility compa-

nies have to be observed.

The heat pump is to be connected to the heat source

and heat distribution systems in accordance with all

applicable provisions.

1.3 Energy-Efficient Use of the Heat

Pump

By operating this heat pump you contribute to the

protection of our environment. A prerequisite for an

efficient operation is the proper design and sizing of

the heating system and the heat source system. In

particular, it is important to keep water flow

temperatures as low as possible. All energy

consumers connected should therefore be suitable

for low flow temperatures. A 1 K higher heating water

temperature corresponds to an increase in power

consumption of approx. 2.5 %. Underfloor heating

systems with flow temperatures between 30 °C and
40 °C are optimally suited for energy-efficient
operation.