Warning: The unit must be permanently connected to the protective ground before operation. The
cross-sectional area of the protective earthing / grounding conductor shall be at least 10 mm
2
or
6 AWG.
Warnung: Diese Anlage muss vor der Inbetriebnahme ständig an den Schutzleiter angeschlossen
werden. Die Querschnittsfläche des Schutzerdungsleiters soll mindestens 10 mm
2
oder 6 AWG
betragen.
警告:进行设备操作前,请确保设备永久接地,并且确保接地线截面不小于
10 mm
2
或6 AWG。
Warning: Before the power cable is connected, it must be confirmed that the power cord complies
with the requirements of the actual installation (see power cord table)
Warnung: Überprüfen Sie vor dem Anbringen der Zuleitung immer, ob das von Ihnen verwendete
Kabel den Anforderungen entspricht (siehe Netzkabel-Tabelle).
警告
: 在进行电源线连接前,请确保电源线与实际安装要求一致(参考电源线表格)。
Warning Power Cord Table:
The power cord set must be approved for the country where it is used.
WARNUNG Netzkabel Tabelle:
Das Netzkabel muss für das Land, in dem es verwendet wird, zugelassen werden.
警告:电源线表格:
电源线组件必须满足使用的国家认证要求。
U.S.A. and
Canada
•
The cord set must be UL approved and CSA certified
•
The minimum specification for the flexible cord is:
•
No. 14 AWG
•
Type SV / SVT or SJ / SJT or SPT-2
•
3 conductor
•
The cord set must have a rated current carrying capacity of at least 20A.
•
The attachment plug must be an earth-grounding type with a NEMA 5-20
(20A, 125V) or NEMA 6-20 (20A, 250V) configuration
United Kingdom
•
The supply plug must be a 2 pole plug with dual earth contacts as per
IEC 60309.
•
The mains cord must <HAR> or <BASEC> marked and be of type
H05VVF3G1.50 (minimum)
Europe
•
The supply plug must comply with CEE 7/7 (“SCHUKO”)
•
The mains cord must <HAR> or <BASEC> marked and be of type
H05VVF3G1.50 (minimum)
Denmark
•
The supply plug must comply with the Heavy Current Regulations, section
107-2-D1 or EN60309-2.
Switzerland
•
The supply plug must comply with SEV/ASE 1011
Argentina
•
The power cord set must be certified by UL, IRAM, TÜV (or other
authorized certification body), for three conductors cables.
•
The attachment plug must be an earth-grounding type with an
IRAM-2073 (20 A, 250 V).
中国
•
电源线组件必须通过
CCC 认证。
•
必须使用符合
GB1002,额定值为 250V/16A 的单相两级带接地插头
•
电源线最小线径为
1.5mm
2
The appliance coupler (the connector to the unit and not the connector to the wall plug) must have a
configuration for mating with an EN 60320 / IEC 320 C19 appliance inlet.
- H3C S12500-X Series Switches H3C S10500 Series Switches H3C S9800 Series Switches H3C WX5500E Series Access Controllers H3C S7500E Series Switches H3C WX3500E Series Access Controllers H3C SecPath F1020 H3C SecPath F1030 H3C SecPath F1050 H3C SecPath F1060 H3C SecPath F1070 H3C SecPath F1080 H3C SecPath L1000-E Load Balancing Device H3C SecPath L1000-M Load Balancing Device H3C SecPath L1000-S Load Balancing Device