Data sheet – Emerson Process Management El-O-Matic E and P Series E25-E950 Benutzerhandbuch
Seite 25

Data sheet
Copyright © Emerson Process Management. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website
www.El-O-Matic.com or from your nearest Valve Automation Center USA: +1 813 319 0266 Europe: +31 74 256 10 10 Asia-Pacific: +65 6501 4600
www.El-O-matic.com
A1.204.01 Rev. C
180° DOUBLE ACTING ACTUATOR TORQUE (In.lb.)
180°
Actuator
type
Torque (in in.lb)
Supply Pressure (PSI)
30
40
50
60
70
80
ED
12
44
59
74
89
104
119
PD
60
104
139
175
210
245
281
PD
150
262
351
441
530
620
709
PD
280
493
662
830
999
1167
1336
PD
500
872
1170
1467
1765
2063
2361
PD
750
1297
1740
2182
2625
3068
3511
PD
1100
1912
2566
3219
3872
4525
5179
PD
2500
4407
5913
7418
8923
10429
11934
PD
4000
7440
9981
12522
15064
17605
20146
Note
1. Emerson Process Management recommends that the valve manufacturer supply the
maximum required torque values (Including any adjustments or suggested safety factors for
valve service conditions or application).
Additionally, the valve manufacturer must identify at which position(s) and direction(s) of
rotation (Counter Clock Wise or Clock Wise) these maximum requirements occur.
2. If in doubt, or you require any assistance with sizing actuators, do not hesitate to contact your
nearest Emerson's Valve Automation Division representative.
3. Pressure on port "A" opens the actuator*
4. The actuator is shown in closed position*
5. Do not exceed the maximum supply pressure of 6 bar / 87psi.
(*code A, data sheet A1.503)
A
B
182°
181°
-1°
TORQUE
START
END
ROTATION
Sheet No.:
Date: June 2010