Torque, A1.104.01 rev. b double acting actuator (in.lb.), Double acting actuator torque (in.lb.) 90 – Emerson Process Management El-O-Matic E and P Series E25-E950 Benutzerhandbuch
Seite 10: Data sheet, Double acting torque

Data sheet
Sheet No.:
Date: January 2010
Copyright © Emerson Process Management. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website
www.El-O-Matic.com or from your nearest Valve Automation Center USA: +1 813 319 0266 Europe: +31 74 256 10 10 Asia-Pacific: +65 6501 4600
www.El-O-matic.com
A1.104.01 Rev. B
DOUBLE ACTING ACTUATOR TORQUE (In.lb.)
90°
Actuator
Torque of double acting actuators (in In.lb)
Supply pressure (psi)
Type Size
30
35
40
45
50
55
60
70
75
80
90
100
120
ED
12 43.9
51.4
58.9
66.4
73.9
81.4
88.9
104
111
119
134
149
179
ED
25 81.4
95.3
109
123
137
151
165
193
206
220
248
276
332
ED
40 153
179
205
231
257
283
309
361
387
413
466
518
622
ED
65 233
272
312
352
392
431
471
551
590
630
709
789
948
ED
100 344
402
461
520
578
637
696
813
872
930
1048
1165
1400
ED
150 551
645
739
833
927
1021
1115
1303
1397
1491
1680
1868
2244
ED
200 754
883
1011
1140
1269
1398
1527
1784
1913
2042
2299
2557
3072
ED
350 1310
1534
1757
1981
2205
2428
2652
3100
3323
3547
3994
4442
5337
ED
600 2226
2606
2986
3366
3747
4127
4507
5267
5647
6028
6788
7548
9069
ED
950 3323
3890
4458
5025
5593
6160
6728
7862
8430
8997
10132 11267 13537
ED
1600 5493
6431
7369
8307
9245
10183 11121 12998 13936 14874 16750 18626 22379
PD
2500 8774 10273 11825 13270 14768 16267 17847 20858 22363 23869 26880 29891 35912
PD
4000 14874 17414 19962 22495 25035 27576 30127 35210 37751 40293 45375 50458 60623
Note
1. Emerson Process Management recommends that the valve manufacturer supply the maximum required torque
values (Including any adjustments or suggested safety factors for valve service conditions or application).
Additionally, the valve manufacturer must identify at which position(s) and direction(s) of rotation
(Counter Clock Wise or Clock Wise) these maximum requirements occur.
2. If in doubt, or you require any assistance with sizing actuators, do not hesitate to contact your
nearest Emerson's Valve Automation Division representative.
3 Pressure on port "A" opens the actuator*
4 The actuator is shown in closed position*
(* code A, data sheet A1.503)
91.5°
-0.5°
91°
A
B
CLOSED
OPEN
Rotation
Start
End
Torque
DOUBLE ACTING TORQUE