Building-in instructions for the installer – Zanussi ZOB 482 XL Benutzerhandbuch

Seite 42

Advertising
background image

42

Fig. 13

To ensure correct operation of the built-in assembly, the kitchen
cabinet and the recess for the built-in appliance must have
suitable dimensions. When the appliance is fitted-in, there
must be no open spaces left and it must be closed on all
sides by the kitchen furniture to prevent the possibility of
inadvertently touching “live” (current carrying) parts of the
oven. All parts ensuring such a protection, including any
covering panel (for instance, if the appliance is installed at the
end or at the beginning of a kitchen counter) must be fastened
in such a way as to prevent removal of the same without the
aid of some tool. This appliance can be placed with its back
and with one side close to appliances or walls of higher
height. The other side, instead, must be placed close to
furniture or appliances, having the same height.

Overall oven dimensions (Fig. 13)

Building-in

Instructions for the Installer

The instructions given below are designed

specifically for a qualified installer and should

aid him or her to perform all installation,

adjustment, and maintenance operations with

absolute precision and in compliance with all

current legislation and regulations. We

strongly recommend that all operations for

the installation of your cooker be carryed out

by Qualified Personnel in accordance with

existing rules and regulations.

Electrical connection

Prior to making the electrical connection, make sure that:

— the protection fuse and the domestic wiring

system are suitable to carry the total electric load of the

oven (see rating plate);

— your domestic wiring system has an efficient

earth connection in compliance with rules and laws in

force;

— the wall socket or the omnipole switch used for

the electrical connection can easily be reached after the

oven is built in.

This appliance is delivered without an electric supply cable,

therefore, you will have to fit to it a supply cable with standard

plug, suitable for the total electric load shown on the rating plate.

The plug is to be inserted into a suitable wall socket. If you

require a direct connection to the electric network (mains), it will

be necessary to fit between the appliance and the mains an

omnipole switch, with a minimum gap between contacts of 3

mm, suitable for the required load and in compliance with rules

in force. The green & yellow ground wire must not be interrupted

by the switch, and should be 2-3 cm longer than the phase and

neutral wires. The supply cable must in all cases be laid out in

such a way as to ensure that it does not reach at any given

point a temperature 50°C higher than the ambient temperature.

Suitable power supply cables are the following types,

considering the respective necessary section of cable: H07 RN-

F, H05 RN-F, H05 RR-F, H05 VV-F, H05 V2V2-F (T90), H05

BB-F.

Terminal block

The oven is fitted with an easily accessible terminal block

which is designed to operate with a single-phase power

supply of 230 V (Fig. 12).

The manufacturer disclaims any liability if the safety

measures are not observed.

Fig. 12

Advertising