English – Burkert Type 2031 Benutzerhandbuch

Seite 13

Advertising
background image

2030/2031 - 13

english

Work steps:
• Turn valve down and place on cover (Pos. 18).
• Separate valve body (Pos. 22) from actuator by unfastening the screws

(Pos. 24).

• Unbutton diaphragm (Pos. 21).
• Hold actuator square of the actuator housing (Pos. 1).
• Dismount cover with special key (Pos. 18).
• Dismount position indicator (Pos. 15).
• Remove spring (Pos. 11).
• Use 4.5 mm screw driver to unfasten nut (Pos. 14), and hold against on

lower spindle end (Pos. 4).

• Remove spindle (Pos. 4) and two-part pressure pieces (Pos. 5) though

the bottom.

• Push piston (Pos. 9) and other support disc (Pos. 7) through the top.

CAUTION!

Do not damage seal surfaces on actuator housing (Pos. 1)!

• Remove lower intermediate disc (Pos. 7) and o-ring (Pos. 8).
• Slightly greases over inner surface of actuator ring (Pos. 1):

- for PA-actuator with "Lagermeister SL"
- for PPS-actuator with "Amblygon TA 30-1".

• Reinsert spindle* (Pos. 4) and two-part pressure piece (Pos. 5) from

below.

• Insert pressure springs (Pos. 6).
• Push lower intermediate disc (Pos. 7) and o-ring (Pos.8) onto spindle

(Pos. 4) until it stops.

• Mount piston, thus prestressed spring (Pos. 6) with piston (Pos. 9) by

hand.

• Slide intermediate disc (Pos. 7) over spindle (Pos. 4).
• Wet spindle thread with liquid glue “LOCTITE 274”.
• Mount nut (Pos. 14) and release CFB-spring against it.
• Firmly tighten nut (Pos. 14), thus counter holding from below with 4.5mm

screw driver.

• Install position indicator (Pos. 15).
• Place o-ring (Pos. 17) onto seal of actuator housing.
• Slightly grease over cover thread as on actuator housing.

* Use mounting sleeve (see 5.2 Mandrells)

Advertising