WolfVision VZ-C3D User Manual Benutzerhandbuch

Seite 12

Advertising
background image

In some rooms the built-in infrared receiver of the Ceiling Visualizer may not be enough. In this case
connect the supplied external infrared receiver to the IR-sensor plug (#15) and position the IR-sensor
somewhere on the ceiling (or in the room) where the users normally point the remote control at.

External Infrared (IR) Sensor

IMPORTANT

11

Ethernet / LAN Port

10BASE-T/100Base-TX

The LAN port (#14) makes the Visualizer a part of the internal computer network and it can be used for
communication over the Internet, if it is assigned an official (WAN) IP address.
Administrators of a larger number of Visualizers can use the LAN port to control, support and update all of
their units from their local desktop PC.
The list of applications for the Visualizers LAN port is constantly increasing. It can be used for controlling,
capturing still images, viewing live video streams, firmware updates, adjustments, menu settings and
maintenance purposes.
The following protocols are supported: TCP/IP, IGMP, UDP and ARP.

d (tested) internet b

are:

/Firefox

In order to prevent unauthorized users from logging into the Visualizer over the network, it is possible to set
administrator and user passwords. The transmission of the passwords over LAN is encrypted with Md5.

The Visualizer offers streaming of live images in UDP Multicast/Unicast and TCP Singlecast mode.
Technical Background: UDP Multicast works like a broadcast - many clients are watching the same video
stream. In Multicast mode the bandwidth is always the same, no matter how many computers are
connected. However as many routers do not support Multicast, UDP Unicast can be used instead for point-
to-point connection (one client is possible).
In TCP Singlecast mode each computer opens a separate connection to the Visualizer, which requires a lot
of bandwidth if many clients are connected (max. 64 clients are possible).

Supporte

rowsers

Internet Explorer, Netscape Navigator and Mozilla

.

By default, DHCP is activated to receive all network settings automatically.
Possible image transfer resolution up to FullHD (1080p).

Please check the separate description of "Built-In WebServer" on our internet homepage at:
www.wolfvision.com/support (or on the supplied CD-Rom).

For full functionality JAVA version 7 or higher is necessary.
For full functionality following ports are necessary: 50915, 50913, 8800 and 8801 (by default).

The

to control the Visualizer through an external device, such as a room control

system that is used to integrate conference rooms.

LAN port (#14) can be used

The complete serial protocol can be found on our internet website under: www.wolfvision.com/support