Cleaning, Important, Firmware upgrades – WolfVision VZ-C3D User Manual Benutzerhandbuch

Seite 15: Infrared remote control, Exchanging fuses maintenance

Advertising
background image

14

WARNING:

To clean the optical parts inside, the unit has to be opened!

Opening the unit is reserved for WolfVision or authorized service personnel!

The unit might be in need of adjustment after opening.

Cleaning

Cabinet:

Clean the cabinet by gently wiping it with a soft, lint free cloth.

Glass:

Clean the glass by gently wiping it with a soft, lint free cloth (do not use a paper tissue!). Clean by

breathing on the glass to create moisture then wipe with lint-free cloth (If not clean, use special
optical cleaner only!).

Never use strong cleaning agents such as acetone or benzene!
These substances can damage the surface and anti-reflex coating!

Please note that dust on the lenses inside the unit and on the glass has only little effect to picture quality
(as it is out of the focal range).

IMPORTANT

The software (firmware) of your Visualizer (including the o

) can easily be upgraded to the

latest version via Ethernet (LAN).
Firmware update files can be downloaded for free at www.wolfvision.com/support. Updates can be
made with the WolfVision Connectivity Software.
Alternatively, the firmware can be updated in the on-screen menu (Advanced Settings / Device Info),
provided the Visualizer is connected to the Internet. By selecting the line ”Check For FW Update”, the
Visualizer checks the WolfVision server for newer firmware files. Follow the on-screen instructions to start
the update process.

n-screen HELP

Firmware Upgrades

Please note that an infrared remote control can only be used up to a certain distance from the unit. Objects
situated between the Visualizer and the infrared remote control, and weak batteries, interfere with
reception.

Infrared Remote Control

CAUTION
Risk of explosion if batteries are replaced by an incorrect type.
Dispose of used batteries according to the instructions. Recycle the batteries.

ATTENTION
Il y a danger d‘explosion s‘il y a remplacement incorrect de la batterie. Remplacer uniquement avec une
batterie du même type ou d‘un type équilanent recommandé par le constructeur.
Mettre au rebut les batteries usagées conformément aux instructions du fabricant. Recycler les batteries.

If the Visualizer can only be controlled from a close distance, you may
need to change the batteries.
If the Visualizer cannot be controlled at all with the infrared remote control,
you may need to check the code (see page 5) or to change the batteries.
Open the cover on the back of the remote control and replace both 1.5V
AAA (Code LR03) batteries with new ones of the same type.
Check the polarity of the batteries!

Disconnect the power cord (#9) before changing the fuses!
The fuses (#11) are situated behind a small lid at the power socket.
It can easily be opened with a small screwdriver etc.. Remove the socket, exchange the fuse(s) carefully,
and put back the socket the right way round into the socket holder.

The type of fuse is: T 0.8A. Do not use any other type !

Change the fuses for new ones and switch the unit on. If the fuse fails again contact your Visualizer dealer!