FWD-50PX3

6. Priority Signal Select Function

(a) Mode Control

Syntax

Header

Category

Function

Data1

Data2

Check Sum

Enquiry

0x83

0x00

Code Table (2-a) [a]

Code Table (2-d)

0xFF

0xXX

Answer

Header

Answer

Return to Data Size

Return Data1

Data2

Check Sum

Enquiry

0x70

0x00

0x02

Code Table (2-a) [b]

0xFF

0xXX

Completed

Code Table (2-a)

[a]Function

[b]Range/Switch Code

Command
Control

Enquiry

Standby

Power On

0x77

Priority Signal Select

0x00

Input1 Auto

No

Yes

Disable

Enable

0x01

Input1 RGB

0x02

Input1 YPbPr

Code Table (2-d)

Input Select

0x00

HD15

0x01

Option1

0xFF

Option2

(b) Color Matrix

Syntax

Header

Category

Function

Data1

Data2

Data3

Data4

Check Sum

Control

0x8C

0x00

Code Table

0x04

Code Table

Code Table

Code Table

0xXX

(1-b) [a]

(1-c)

(1-b) [b]

(1-d)

Syntax

Header

Category

Function

Data1

Data2

Check Sum

Enquiry

0x83

0x00

Code Table (1-b) [a]

Code Table (1-c)

Code Table (1-d)

0xXX

Answer

Header

Answer

Check Sum

Control

0x70

0x00

0x70

Completed

0x70

0x03

0x73

Command Canceled

Answer

Header

Answer

Return to

Return Data1

Return Data2

Return Data3

Check

Data Size

Sum

Enquiry

0x70

0x00

0x04

Code Table (1-c)

Code Table (1-b) [b]

Code Table (1-d)

0xXX

Completed

Code Table (1-b)

[a]Function

[b]Range/Switch Code

Command
Control

Enquiry

Standby

Power On

0x1D

Color Matrix

0x00

YCbCr

Yes

Yes

Disable

Enable

0x01

YPbPr