Sony FWD-50PX3 Benutzerhandbuch

Seite 23

Advertising
background image

21

FWD-50PX3

(e) 8bits Register

Syntax

Header

Category

Function

Data1

Data2

Check Sum

Enquiry

0x83

0x30

Code Table (4-b)

0xFF

0xFF

0xXX

Answer

Header

Answer

Return to Data Size

Return Data1

Check Sum

Enquiry

0x70

0x00

0x02

Code Table (4-b)

0xXX

Completed

Code Table (4-b)

*

Function

Return Data

Unit

0x07

Digital 3.3 V

0x00-0xFF

0x08

Main Power (Vs)

0x00-0xFF

0x09

Digital 5 V

0x00-0xFF

0x0A

Temp1

0x00-0xFF

0x0B

Temp2

0x00-0xFF

0x0C

Temp3

0x00-0xFF

0x10

Analog 9 V

0x00-0xFF

0x11

Shutdown Log

0x00-0xFF

0x12

Digital 3.3 V (Failure)

0x00-0xFF

0x13

Digital 5 V (Failure)

0x00-0xFF

0x14

Analog 9 V (Failure)

0x00-0xFF

0x15

Main Power (Va)

0x00-0xFF

0x16

Analog Power 12 V

0x00-0xFF

(f) Shutdown Log

Syntax

Header

Category

Function

Data1

Data2

Check Sum

Enquiry

0x83

0x30

0x11

0xFF

0xFF

0xC2

Answer

Header

Answer

Return to Data Size

Return Data1

Check Sum

Enquiry

0x70

0x00

0x02

Shutdown Log

0xXX

Completed

Code Table (4-c)

Return Data1: 0x00-0xFF

Code Table (4-c)

Shutdown Information

bit0

Reserved

bit1

1: FAN Sensor Abnormal

0: Normal

bit2

1: Panel Voltage Abnormal

0: Normal

bit3

1: Temperature Sensor Abnormal

0: Normal

bit4

Reserved

bit5

1: Power Abnormal (3.3 V, 5 V)

0: Normal

bit6

1: Analog Power Abnormal (12 V, 9 V, 5 V)

0: Normal

bit7

Reserved

* FWD-50PX3 returns not the AD value but the

display value.

..... For function 0x08 and 0x15

When the display value is 190 V, 0xBE (190) is

returned.

..... For function 0x0A, 0x0B and 0x0C

When the display value is 50 deg, 0x32 (50) is
returned.

When the display value is -20 deg, 0xEC is
returned.

..... For function 0x07, 0x09, 0x10, 0x12, 0x13, 0x14

and 0x16

When the display value is 3.0 V, 0x1E (30) is
returned.