5 transport and storage, 6 installation, Mechanical installation – Festo DRQD-40 ... 50-... Benutzerhandbuch

Seite 46: Transpor t and storage, Installation, 5transport and storage, 6installation

Advertising
background image

DRQD−...

Festo DRQD−... 0907e English

46

For use of the mid−position module DRQD−...−

Z1:

Note
The DRQD−...−

Z1 can be destroyed by incorrect use.

S Make sure that the following points are observed:

Ĉ The shortest permissible cycle time (è Commissioning)
Ĉ Supply air flow control of the mid−position module.

The shortest permissible cycle time of the semi−rotary drive increases
through the use of the mid−position module.

5

Transport and storage

S

Take into account the weight of the DRQD:

It weights up to 20 kg.

6

Installation

Mechanical installation

Note
S Handle the DRQD with care so that the drive shaft is not damaged.

This applies in particular to the following points:

1. Place the DRQD so that you can easily reach the operating parts and connecĆ

tions.

2. Fasten the DRQD in one of the following ways:

ć Double screw connector with centring sleeve in the through−holes

aA

ć With four screws in the threaded holes

7

ć Dovetail mounting (only for DRQD−...−SD../−E..).

Advertising