8

2 Installation

2.2 Connection dTRANS T03 B - Type 707031/...

Connection for

Terminals

Supply
voltage
7.5 — 30V DC
or
current output
4 — 20mA

+1
-2

R

B

= burden resistance

U

b

= supply

voltage

Analog inputs

Resistance
thermometer
in 2-wire
circuit

3
5
6

R

L

0

as standard

R

L

= lead resistance

per conductor

Resistance
thermometer
in 3-wire
circuit

3
5
6

R

L

11

R

L

= lead resistance

per conductor

H

When mounting the transmitter Type 707031/... on the rail,
using the mounting bracket (part no. 00352463), make sure
to route the cables in accordance with the EMC regulations.

Setup

R

B

U

b

7.5V