21

Connection:

Connect the setpoint potentiometer (10 k

lin.

) to the terminals

42, 43, 44 or the selected master-voltage to the terminals 43(+)
and 44(-) of the 2003 board.

Connect terminal 41 to terminal 8 of the 470 / 480 controller.

When using the setpoint potentiometer provided, the mechanical
screw joint must be provided with an additional PE connection
and the connections must be insulated or covered.

Set the trimmer "V

master - coarse

" to the right stop.

Reinstall the protection cover. (Use the original plastic cover for
470 controllers!

3.2

Terminal-connection diagram

The terminal-connection diagram shows the wiring between the
2003 option board with setpoint potentiometer and the 470 / 480
controller.

A

S

E

Setpoint potentiometer

10 K lin

470 / 480

2003

7

8

9

41

42

43

44

Remove the setpoint-potentiometer connection from the terminals
7, 8, 9 of the basic instrument and connect them to the 2003 option
board!