Safety instructions

Residual hazards

1

l

46

EDKLCMW3024−SPS DE/EN 7.0

1.2

Residual hazards

Protection of persons

ƒ

The X2x power connector contacts can conduct hazardous voltages if the motor
starter is connected to the mains. Therefore, disconnect the motor starter before
carrying out any work on it.

ƒ

The X2x power connector contacts also conduct hazardous voltages when the motor
starter is disabled. Depending on the risk analysis of the machine/system, you may
have to take additional protective measures.

ƒ

Operation at ambient temperatures > 40°C:
– The operating temperature of the motor starter housing is > 60°C.
– Depending upon the risk analysis of the machine/system, you may have to use

additional protective covers.

Motor protection

ƒ

The connected motor can overheat if
– Motors are operated on the motor starter that do not feature temperature

monitoring with PTC thermistor (PTC) or thermal contact (NC contact)

– Temperature monitoring with PTC thermistor (PTC) or thermal contact (NC

contact) is not connected to the motor starter

– Temperature monitoring is not activated (C0119)
– The set rated motor current for I

2

t monitoring is not adjusted to the motor (C0120)

– I

2

t monitoring is switched off (C0121)